49
Group 22: PM Motor Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Magnetic Pole.
9. Current
Abnormity
Occurs while
Loop
Adjustment.
10.Reserved
11. Stator
Resistance
Measurement
Timeout
22-23
22-24
Reserved
22-25
Detection Mode
Selection of
Initial Magnetic
Pole
0: Upon the
angle before
stopping
2
(Note7)
1: Mode 1
2: Mode 2
22-26 Estimator Mode
0~1(in PMSLV
mode)
0
22-27
Voltage
Command of
Mode 2
5~120
(Note7)
(22-25=2 or 22-
26=1 is
enabled)
50
22-28
Divider Ratio of
Mode 2
0~8
(Note7)
(22-25=2 or 22-
26=1 is
enabled)
2
22-29
Flux-weakening
Voltage
Command
Restriction
80~110
(Note7)
(relative to
parameter 22-
18)
100
22-30
SPM Speed
Estimation
Gain
(Note7)
1~150 85 Note4
22-31
SPM Speed
Estimation
Filter Value
(Note7)
1~2000 60 Note4
22-32
MTPA
Selection
0: Disabled
1: Mode 1
0 Note7
22-33 MTPA Gain 000~400% 200 Note7
22-34
IPM Estimator
Gain
1~300.0 180 Note7
22-36
PM Motor Type
Selection
0: Normal PM
motor
0
Note
8
1: DVEN Motor
22-37
PM Motor
Horse Power &
RPM
1.0.75KW
1800RPM
0
Note
8
4.1.5KW
1800RPM
7.2.2KW
1800RPM
Group 22: PM Motor Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
10.3.7KW
1800RPM
13.5.5KW
1800RPM
16.7.5KW
1800RPM
19.11KW
1800RPM
22.15KW
1800RPM
25.18.5KW
1800RPM
28.22KW
1800RPM
.
Chapter 4 Troubleshooting
and Fault Diagnostics
4.1 General
Inverter fault detection and early warning / self-
diagnosis function. When the inverter detects a
fault, a fault message is displayed on the
keypad. The fault contact output energizes and
the motor will coast to stop (The stop method
can be selected for specific faults).
When the inverter detects a warning / self-
diagnostics error, the digital operator will
display a warning or self-diagnostic code, the
fault output does not energize in this case.
Once the warning is removed, the system will
automatically return to its original state.
4.2 Fault Detection Function
When a fault occurs, please refer to Table 4.1
for possible causes and take appropriate
measures.
Use one of the following methods to restart:
1. Set one of multi-function digital input
terminals (03-00, 03-07) to 17 (Fault reset);
activate input
2. Press the reset button on the keypad.
3. Power down inverter wait until keypad goes