EasyManua.ls Logo

TECO A510s Series - Page 112

TECO A510s Series
674 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-22
Group 00: Basic Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
00-33
Modified
Parameters (only
for LCD keypad)
0:Disable
0 - O O O O O O O *7
1:Enable
00-34
~
00-40
Reserved
00-41 User parameter 0
Set 13-06 = 1, start user
parameter. The setting
range is 00-01 ~22-31,
but except 00-41~00-56
and group 17 (only for
LCD keypad)
00-41 - O O O O O O O *7
00-42 User parameter 1 00-42 - O O O O O O O *7
00-43 User parameter 2 00-43 - O O O O O O O *7
00-44 User parameter 3 00-44 - O O O O O O O *7
00-45 User parameter 4 00-45 - O O O O O O O *7
00-46 User parameter 5 00-46 - O O O O O O O *7
00-47 User parameter 6 00-47 - O O O O O O O *7
00-48 User parameter 7 00-48 - O O O O O O O *7
00-49 User parameter 8 00-49 - O O O O O O O *7
00-50 User parameter 9 00-50 - O O O O O O O *7
00-51 User parameter 10 00-51 - O O O O O O O *7
00-52 User parameter 11 00-52 - O O O O O O O *7
00-53 User parameter 12 00-53 - O O O O O O O *7
00-54 User parameter13 00-54 - O O O O O O O *7
00-55 User parameter 14 00-55 - O O O O O O O *7
00-56 User parameter 15 00-56 - O O O O O O O *7
00-57
SV High Speed
Mode
0: SV High Speed
Mode1
0 - X X X O X X X
1: SV High Speed
Mode2
*: Refer to the following attachment 1.
**: Before to set up 00-32 Application, it should do initialized setting (parameter 13-08) first. When setting
00-32, the I/O port function changed automatically. To avoid accident, be sure to confirm the I/O port
signal of inverter and external terminal control.
*** If parameter 00-27 is set to ND mode, group 02 motor 1 parameter will automatically adjust to more
than 1 class of it.
If parameter 00-27 is set to HD mode, group 02 motor 1 parameter will automatically adjust to the same
class of it.
It is suggested that parameter 00-27 be set first before motor performs auto-tuning because the
parameter will make the motor parameter automatically be changed.
***** If the maximum output frequency of motor is over 300HZ,the frequency resolution is changed to
0.1Hz.

Other manuals for TECO A510s Series