1.7.6 DISPLAY INDICATIONS
On: Appliance in cooling mode (Ref. A9 Fig. 15).
On: Appliance in heating mode (NOT ACTIVE) (Ref. B1 Fig. 15).
Flashing: Appliance ready for cooling (Ref. A9 Fig. 15).
On: Alarm condition (Ref. A1 Fig. 15).
1.7.7 THERMOSTAT ADJUSTMENT
Refer to Figure 15 for button identification
1) The water temperature can be set between 5°C and 15°C (41°F - 59°F). To change it:
a. Press and hold the SET button (Ref. A8) for 3 seconds. The currently set value will be displayed, and the
unit of measurement icon (C or F Ref. C3) will start flashing.
b. Adjust the value using the buttons. and (Rif. C2 e A7).
c. Press the SET button (Ref. A8) to confirm the set value.
2) To adjust other parameters such as operating hysteresis (Hy) or sensor calibration (Ot). Access the
programming menu by pressing and holding the SET+ (Ref. A8 e A7). The icon of the selected unit of
measurement begins to flash (C or F Ref. C3) and Hy appears. Scroll through the parameters using the buttons
and (Ref. C2 and A7) until you see the desired parameter.
f. Press the SET button (Ref. A8), and the currently set value will be displayed.
g. Adjust the value using the buttons and (Ref. C2 e A7).
h. Press the SET button (Ref. A8) to confirm the set value and proceed to the next parameter.
i. Press SET + (Ref. A8 and C2) to exit the programming mode.
NOTE: If no button is pressed for 30 seconds, all the set values will be saved, and the appliance
will be ready to operate.
Parameter Pre-set Value
Description
Range
Hy 1°C
This parameter regulates the hysteresis, which is the
differential for the operation of the appliance
0,5 ÷ 10°C
1 ÷ 45°F
rL xx.x
Thermostat firmware version.
Read-only parameter.
-
Tab. 1-2
1.8 TRANSPORT AND STORAGE
The appliance should be handled gently and positioned in an upright position using the provided handles. It
should be placed on a flat surface.
1.9 DEMOLITION AND DISPOSAL
The label with the crossed-out waste bin symbol on the product indicates that the product should
not be disposed of through the normal household waste disposal procedure. To prevent potential
harm to the environment and human health, please separate this product from other household
waste so that it can be recycled in accordance with environmentally responsible procedures. For
more information on available collection centers, please contact your local government office or
the product retailer. These instructions apply only to customers within the European Union, in accordance with
the European Parliament directive on Waste Electrical and Electronic Equipment (WEEE) and the regulations
governing its transposition and implementation into various national legal systems. For other countries, please
contact your local government to explore the possibility of recycling your product.