On the display, the
message “HA2”
appears
(overheating).
Dirty air filter.
Clean the filter as indicated in the Cleaning
chapter.
Room temperature too high.
Restore optimal environmental conditions. The
maximum allowable room temperature is 32°C
(90°F)
Blocked ventilation ducts.
Clear the vents or place the conditioner in a
suitable environment.
Ventilation system malfunction. Contact the local TECO S.r.l. dealer.
On the display, the
message “P1”
appears
Water temperature probe
malfunction.
Contact the local TECO S.r.l. dealer.
On the display, the
message “P2”
appears
Overheating probe malfunction. Contact the local TECO S.r.l. dealer.
On the display, the
message “HA”
appears.
High water temperature.
Check the proper operation of the pump (not
provided) (Ref. A1 Fig. 12-13).
Ensure that there are no pipe obstructions.
Verify that the cooling function is active.
On the display, the
message “LA”
appears.
Low water temperature.
Check the proper operation of the pump (not
provided) (Ref. A1 Fig. 12-13).
Ensure that there are no pipe obstructions.
The temperature
displayed on the
device's screen
does not match the
actual temperature
of the aquarium
The water does not circulate
correctly within the hydraulic
circuit.
Ensure that there are no pipe obstructions.
Check the efficiency of the pump (not provided).
Long and uninsulated pipes.
Shorten the pipes as much as possible and
thermally insulate them.