1.5.1 TECHNICAL DATA AND SPECIFICATIONS
Specifications
Power supply¹ 230V - 50Hz
Power Consumption 440 W
Water Inlet/Outlet 16 mm - 3/4 in
Water flow² 900 l/h ÷ 1200 l/h - 238 USgal/h ÷ 317 USgal/h
Maximum Pressure 100 kPa - 1 bar - 14,4 PSI
Weight 25 kg - 54,9 lb
Dimensions 310 x 310 x 500 (h) mm - 12,2 x 12,2 x 19,69 (h) in
Refrigerant¹ R290
All data is indicative and subject to change without notice by TECO.
Refer to the technical data label Ref. A3 Fig.4. Contact TECO for other power supplies.
²The indicated flow is the actual flow, not the maximum flow of the pump. Please contact the distributor for pump selection.
Tab. 3-1
1.6 GENERAL CONDITIONS OF USE
1.6.1 ALLOWED USES
To correctly use the appliance, it is advisable to follow the following guidelines:
The appliance described in this manual has been specifically designed for cooling water.
The appliance is suitable for operation in environments with an ideal operating temperature between
+16°C and +32°C (60°F – 90°F).
The appliance must be installed on a flat surface.
Any operation involving manual actions on the appliance must only be done when the appliance is
stationary.
.
1.6.2 PROHIBITED USES
Using the appliance in contrast to the recommended usage guidelines constitutes non-compliant usage.
Here are the guidelines:
It is prohibited to use the appliance in areas with high heat and direct radiation exposure.
It is prohibited to use the appliance in areas with potentially explosive atmospheres.
It is prohibited to use the appliance in excessively dusty areas and/or in the presence of a high
concentration of solid particulates in the air.
It is prohibited to introduce water into the refrigeration unit at a temperature exceeding 30°C (86°F)
or lower than 5°C (41°F).