EasyManua.ls Logo

TECO F510 series - 3.3.5 Wiring for Control Circuit Terminals

TECO F510 series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
Group 16: LCD Function Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
P4
30:Off+P2+P3+
P4
31:Off+P1+P2+
P3+P4
16-36
Selection of
RTC Speed
0: Off
0
1: By Timer 1
2: By Timer 2
3: By Timer 3
4: By Timer 4
5: By Timer
1+2
16-37
Selection of
RTC
Rotation
Direction
xxx0b: RTC
Run1 Forward
Rotation
0000b
x
xx1b: RTC
Run1 Reverse
Rotation
x
x0xb: RTC
Run2 Forward
Rotation
x
x1xb: RTC
Run2 Reverse
Rotation
x
0xxb: RTC
Run3 Forward
Rotation
x
1xxb: RTC
Run3 Reverse
Rotation
0
xxxb: RTC
Run4 Forward
Rotation
1xxxb: RTC
Run4 Reverse
Rotation
Group 17: IM Motor Automatic Tuning
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
17-00
Mode
Selection of
Automatic
Tuning
0: Rotational
Auto-tuning
VF:2
SLV:6
1: Static Auto-
tuning
2: Stator
Resistance
Measurement
3: Reserved
4: Loop Tuning
5: Rotational
Auto-tuning
Combination
Group 17: IM Motor Automatic Tuning
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
(Item: 4+2+0)
Note
6: Static Auto-
tuning
Combination
(Item: 4+2+1)
Note
17-01
Motor Rated
Output
Power
0.00~600.00 -
17-02
Motor Rated
Current
0.1~1200.0 -
17-03
Motor Rated
Voltage
200V: 50.0~240.0
-
400V:100.0~480.0
-
17-04
Motor Rated
Frequency
4.8~599.00
(Note8)
60.0
17-05
Motor Rated
Speed
0~24000 KVA
*a
17-06
Pole
Number of
Motor
2~16 (Even) 4 *6
17-07 Reserved
17-08
Motor No-
load Voltage
200V: 50~240
KVA
*a
400V: 100~480
17-09
Motor
Excitation
Current
0.01~600.00
(15%~70%
motor rated
current)
KVA
*a
1
17-10
Automatic
Tuning Start
0: Disable
0
1: Enable
17-11
Error
History of
Automatic
Tuning
0: No Error
0
1: Motor Data
Error
2: Stator
Resistance
Tuning Error
3: Leakage
Induction
Tuning Error
4: Rotor
Resistance
Tuning Error
5: Mutual
Induction
Tuning Error
6: Reserved
7: DT Error
8: Motor
Acceleration
Error
9: Warning
17-12
Leakage
Inductance
Ratio
0.1 ~ 15.0 3.4
17-13
Slip
Frequency
0.10 ~ 20.00 1.00
17-14
Rotational
Tuning
0: VF Mode
1: Vector Mode
0