46
Group 22: PM Motor Parameters-
only available when PM Control Mode
is selected
Code
Parameter
Name
Setting Range Default
Attribu
te
9: Current
Abnormity
Occurs while
Loop
Adjustment.
10: Reserved
11: Stator
Resistance
Measurement
Timeout
12: Reserved
22-23
PM SLV
acceleration
time
0.1~10.0 1.0
Note2
22-25
Detection
Mode
Selection of
Default
Magnetic
Pole
0: Angle before
Stop
2
(Note8)
Note4
1: Mode 1
2: Mode 2
22-26
Estimator
Mode
0~1 (in PMSLV
mode)
0
Note6
22-27
Mode 2
Voltage
Command
5~120
(Note8)
(22-25=2 or 22-
26=1 is
enabled)
50
Note4
22-28
Mode 2
Frequency
Division
Ratio
0~8
(Note7)
(22-25=2 or 22-
26=1 is
enabled)
2
Note4
22-29
Field-
Weakening
Voltage
Control
80~110
(Note7)
(relative to
parameter 22-
18)
100
Note4
22-30
SPM Speed
Estimation
Gain
(Note7)
1~150
85
Note6
22-31
SPM Speed
Estimation
Filter Value
(Note7)
1~2000
60
Note6
22-32
MTPA
Selection
0: Disabled
1: Mode 1
0
Note7
22-33 MTPA Gain 000~400% 200
Note7
22-34
IPM
Estimator
Gain
1~300 180
Note7
Group 23 Pump & HVAC Function
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
23-00
Function
Selection
0: Disable
0 *7
1: Pump
2: HVAC
Group 23 Pump & HVAC Function
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
3: Compressor
*7
23-01
Setting of
Single &
Multiple
Pumps and
Master &
Slave
Machines
0: Single Pump
0
1: Master
2: Slave 1
3: Slave 2
4: Slave 3
23-02
Operation
Pressure
Setting
0.10 ~ 650.00 4.00 *6
23-03
Maximum
Pressure of
Pressure
Transmitter
0.10 ~ 650.00 10.00 *6
23-04
Pump
Pressure
Command
Source
0: Set by 23-02
0
1: Set by AI
23-05
Display
Mode
Selection
0: Display of
Target and
Pressure
Feedback *
0
1: Only Display
Target
Pressure
2: Only Display
Feedback
Pressure
23-06
Proportion
Gain (P)
0.00~10.00 3.00
23-07
Integral
Time (I)
0.0~100.0 0.5
23-08
Differential
Time (D)
0.00~10.00 0.00
23-09
Tolerance
Range of
Constant
Pressure
23-20=0 : 0.01
~ 650.00
23-20=1 :
1~100
5 *6
23-10
Sleep
Frequency
of Constant
Pressure
0.00 ~ 599.00
(Note8)
30.00
23-11
Sleep Time
of Constant
Pressure
0.0 ~ 255.5 0.0
23-12
Maximum
Pressure
Limit
23-20=0 : 0.00
~ 650.00
23-20=1 :
0~100
50 *6
23-13
Warning
Time of
High
Pressure
0.0 ~ 600.0 10.0
23-14
Stop Time
of High
Pressure
0.0 ~ 600.0 20.0

Other manuals for TECO F510 series