31 
 
 
 
 
Parameter List 
 Function F_ Function Description 
Unit Range 
Factory 
setting 
Page Note
 0 Factory Adjustment    0 32  
1  Accel. time  0.1Sec 0.1 ~ 999 S  5.0  32  *1 *3Accel. Time  
Decel. Time 
2  Decel. time  0.1Sec 0.1 ~ 999 S  5.0  32  *1 *3
Operation mode  3 
0: Forward / Stop, Reverse / Stop
1:Run/Stop, Forward / Reverse 
1 0 ~ 1 0 33 
 
Motor rotation 
direction 
4 
0: Forward 
1: Reverse 
1 0 ~ 1 0 33 
*1
V/F Pattern  5  V/F pattern setting  1  1 ~ 6  1/4  34  *2
6  Frequency upper limit  0.1Hz
1.0 ~ 120Hz 
(1~200)*4 
50/60Hz 35 
*2 *3
Frequency 
upper/lower limit 
7 Frequency lower limit  0.1Hz
0.0 ~ 120Hz 
(1~200)*4 
0.0Hz 35 
*3
SPI frequency  8  SP1 frequency  0.1Hz
1.0 ~ 120Hz 
(1~200)*4 
10Hz 35 
*3
JOG frequency  9  JOG frequency  0.1Hz
1.0 ~ 10.0Hz 
(1~200)*4 
6Hz 35 
 
Start / Stop Control  10 
0: Keypad 
1: Terminal (TM2) 
1 0 ~ 1 0 35 
 
Frequency Control  11 
0: Keypad 
1: Terminal (0~10v / 0~20mA) 
2: Terminal (4~20mA) 
1 0 ~ 2 0 36 
 
Carrier frequency 
control 
12 
Carrier Frequency Setting 
1 
1 ~ 5 
(1~10)*4 
5 36 
 
Torque compensation  13  Torque compensation gain  0.1%  0.0 ~ 10.0%  0.0%  36  *1
Stop method  14 
0:controlled deceleration stop 
1:free run to stop 
1 0 ~ 1 0 37 
 
15 
DC braking time 
0.1S 0.0 ~ 25.5S 0.5S  37 
 
16 
DC braking injection frequency 
0.1Hz 1 ~ 10Hz  1.5Hz  37 
 
DC braking setting 
17 
DC braking level 
0.1%  0.0 ~ 20.0%  8.0%  37 
 
Electronic thermal 
Overload protection  
18 
Protection base on motor rated 
current  
1% 
50 ~ 100% 
(0~200)*4 
100% 38 
 
19 
Multifunction input terminal 1 
(SP1) function 
2 39 
 
Multifunction input 
connection point 
20 
Multifunction input terminal 2 
(RESET) function 
1: Jog 
2: Sp1 
3: Emergency stop 
4: External Base Block 
5: Reset   
6: SP2*4 
5 39 
 
Multi-function output  21 
Multifunction output terminal  1: Operating 
2: Frequency reached 
3: Fault 
3 40