36 
 
 
 
F_11: Speed Control 
= 0: Keypad 
= 1: Analog Speed Pot Terminal (TM2) (0 ~ 10V / 0-20mA)  
= 2: Analog Speed Pot Terminal (TM2) ( 4-20mA )   
 
NOTE 1: 
When jog frequency or Sp1 frequency is 
 switched on, the frequency is setup by Sp1 
speed, the ▲▼ buttons on the keypad is 
 disabled. 
Original setting will be restored after the Sp1  
connection is removed. 
 
NOTE2: 
During the contact closure of the jog function,  
the keypad control remains in a sleep state until  
the jog contact connection is re-opened.   
 
F_12: Carrier Frequency = 1 ~ 10 
 
F_12 Carrier frequency F_12 Carrier frequency F_12 Carrier frequency
1 4 kHz 5  8 kHz 
9 
15 kHz*1 
2  5 kHz  6  10 kHz*1 
10 
16 kHz*1 
3  6 kHz  7  12 kHz*1 
 
4 7.2 kHz 8 14.4 kHz*1    
NOTE: *1: Available for CPU version V1.9 and above. 
  2: If F_12=7~10, the inverter must operator with low load. 
Although an IGBT TYPE inverter can provide a low audible noise level during its operation, it is possible 
that the switching of the high carrier frequency may interfere with external electronic components (or 
other controllers) or even cause vibration in the motor. Adjusting the carrier frequency can usually 
correct this problem. 
 
 
F_13: Torque compensation gain = 0 ~ 10 % 
 
To enhance Inverter output torque patterns according to the B, C voltage points on the V/F pattern (refer 
to F_05 description) and the (F_13) for this feature.   
 
   F
06
0mA 
0V 
4mA 20mA
10V 
 F_11=1 
F_11=2