Programmer`s manual
EZE30
Annex A Page 20 BE 948 a www.tecsis.de
A1 (A2, A3) Set the action for channel 1 (2, 3) sets the source for the value which will trigger the required action of the
output channel relay, according to the settings of the other controls S1 (S2, S3) and H1 (H2, H3). Issuing the A1 (A2, A3)
command without any parameters returns the current value in the form A1:+00001.
NOTE: Remember to store the settings using the SS command before turning off the
power.
3.10 COMMUNICATION SET-UP COMMANDS – AD, BR, DX
AD Set the address of the EZE30 for networking (0-255). Setting the device address to 0 will set the continuously active
mode, where the device becomes permanently active, and will listen and respond to any command on the bus, without the
need for an OP xxx command. Issuing the AD command without any parameters will return the current address. Factory
default setting: 0.
NOTE: this setting will take effect after power on reset (remember to store the setting using the WP command before
turning off the power).
BR Set the EZE30 baud rate. Issuing the BR command without any parameters will return the current baud rate. Set a
new value by issuing the BR command followed by the desired value, in the format BR 115200. Factory default setting:
9600.
NOTE: this setting will take effect after power on reset (remember to store the setting using the WP command before
turning off the power).