11 of 32 © 2007 D 161 - 08/07
Mode Item Field Range Access Description
2
OFF, 40°F
(4.5°C) to Hot
Tub Maximum
Default = 102°F
(39.0°C)
LTD
USEr
InST
ADV
SET HOT TUB OCCUPIED
SECTION B
Select the hot tub temperature for the occupied period.
Note: In the Limited Access Level, the temperature can only
be adjusted by +/-3°F (1.5°C) from the temperature setting
entered prior to entering the Limited access level.
3
OFF, 40°F
(4.5°C) to DHW
Maximum
Default = 130°F
(54.5°C)
LTD
USEr
InST
ADV
SET DHW TANK OCCUPIED SECTION C
Select the domestic hot water tank temperature for the
occupied period.
Note: In the Limited Access Level, the temperature can only
be adjusted by +/-3°F (1.5°C) from the temperature setting
entered prior to entering the Limited access level.
4
OFF, 40°F
(4.5°C) to Floor
Maximum
Default = 80°F
(26.5°C)
LTD
USEr
InST
ADV
SET FLOOR OCCUPIED SECTION D
Select the floor temperature for the occupied period.
Note:
In the Limited Access Level, the temperature can only
be adjusted by +/-3°F (1.5°C) from the temperature setting
entered prior to entering the Limited access level.
1
50 to 239°F
(10.0 to
115.0°C)
Default = 200°F
(93.5°C)
ADV
SETPOINT MAXIMUM SECTION A,
Select the maximum setpoint temperature range
adjustment.
ADJUST MENU
ADJUST Menu (2 of 5)
Continued on next page.