Page #57 background image
Applications
10,
Measure
the
horizontal
difference
between
corresponding
points
on
the
two
waveforms
at
the
50%
rise-time
points
and
calculate
the
phase
difference
using
the
following
formula:
Phase
Difference
horizontal
difference
(divisions)
graticule
^
calibration
(deg/div)
EXAMPLE.
In
Figure
3-8,
the
horizontal
difference
is
0.6
divi¬
sion
with
a
graticule
calibration
of
45°
per
division.
Substituting
the
given
values
into
the
phase-difference
formula:
Phase
Difference
=
0.6
div
x
45°/div
=
27°.