Analyze Wavefor
mData
Description Window
Blackman-Harris
This is the best window for measuring the amplitude of frequencies but worst at resolving
frequencies.
Use Blackman-Harris for measuring predomi nantly single frequency waveforms to look for
higher order harmonics.
Using Reference Waveforms
Create a reference waveform to store a waveform. For example, you might do this to set up a standard against which to
compare other waveforms. To use the reference waveforms:
1. Push Ref R. This brings up the lower-bezel
reference menu.
2. Use the resulting lower-bezel menu
selections to display or select a reference
waveform
.
(R1) |(On)
3-May-07
(R2) |(Off)
MSO2000B and DPO2000B Series Oscilloscopes User Manual 103