Compliance Info
rmation
Safety Compliance
EC Declaration of Conformity Low Voltage
Compliance was demonstrated to the following specication as listed in the Ofcial Journal of the E uropean Communities:
Low Voltage Directive 2006/95/EC.
EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use.
U.S. Nation
ally Recognized Testing Laboratory Listing
UL 61010-1:2004, 2
nd
Edition. Standard for electrical measuring and test equipment.
Canadian Certication
CAN/CSA-
C22.2 No. 61010-1:2004. Safety requirements for electrical equipment for measurement, control, and
laboratory use. Part 1.
Additional Compliances
IEC 61010-1: 2001. Safety requirements for electrical equipment for measurement, control, and laboratory use.
Equipment Type
Test and measuring equipment.
Safet
y Class
Class 1 grounded product.
Pollution Degree D escription
Ame
asure of the contaminants that could occur in the environment around and within a product. Ty pically the internal
environment inside a product is considered to be the same as the external. Products should be used only in the environment
for which they are rated.
Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally
en
capsulated, hermetically sealed, or located in clean rooms.
Po
llution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is
caused by condensation m ust be expected. This location is a typical ofce/home environment. Temporary condensation
occurs only when the product is out of service.
Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation.
T
hese are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct
sunshine, rain, or direct wind.
Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical
outdoor locations.
MSO2000B and DPO2000B Series O scilloscopes User Manual vii

Table of Contents

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals