EasyManuals Logo

Tektronix FG 5010 User Manual

Tektronix FG 5010
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
П
n
П
n
1
П
n
7
7
П
n
1
C
TRIGGER
(
U1730-9
)
SELECTED
SQWV
(
U1732-9
)
U1720B
-
6
REV
JUL
1982
U1730B
-
15
U1732A
-
2
U1720A
-
3
TRIGGER
(
U1730-9
)
SELECTED
SQWV
(
U1732-9
)
U1730B
-
15
U1730A
-
2
U1720A
-
3
TØ
T
I
T1
T2
T3
Main
Loop
.
Finally
,
at
t8
,
the
signals
coincide
,
and
at
t9
,
the
very
short
pulses
that
mark
phase
tracking
begin
to
appear
,
and
the
inner
latches
assume
the
detection
function
.
T
The
output
signal
from
U1720A
is
a
bipolar
drive
signal
that
drives
one
half
of
the
Charge
Pump
.
The
output
of
U1720C
is
a
similar
signal
that
drives
the
other
half
of
the
Charge
Pump
.
From
pin
3
of
U1730A
and
pin
14
of
U1732B
,
two
signals
are
applied
from
the
Phase
Detector
Logic
to
the
Lock
Detector
circuit
.
As
long
as
the
inner
latches
con
trol
the
phase
-
lock
process
,
both
of
these
output
lines
stay
high
,
and
the
CPU
is
informed
that
the
signals
are
locked
.
If
either
of
the
outer
latches
sets
,
that
output
line
goes
low
to
warn
the
CPU
that
the
signals
are
no
longer
locked
together
.
[
]
Fig
.
4-16
.
Phase
Detector
Logic
signals
while
locking
on
.
T4
11
[
1
|
T5
T6
1
|
T7
Theory
of
Operation
-
FG
5010
1
1
T8
|
1
1
T9
Fig
.
4-17
.
Phase
Detector
Logic
signals
when
trigger
is
more
than
twice
square
-
wave
frequency
.
|
3467-39A
3467-23A
In
the
absence
of
a
trigger
,
U1310F
holds
U1730A
reset
to
force
the
Main
Loop
frequency
down
,
to
prevent
phase
detector
lock
up
.
Lock
Detector
This
circuit
operates
off
the
drive
from
the
frequency
de
tector
portion
of
the
Phase
Detector
Logic
circuits
.
The
cir
cuit
is
a
positive
AND
-
gate
that
is
formed
by
Q1840
,
Q1842
,
and
Q1834
.
When
both
inputs
of
the
gate
are
high
,
neither
Q1842
nor
Q1840
conduct
.
All
of
the
current
through
R1836
,
therefore
,
passes
through
Q1834
and
R1835
,
and
the
output
is
high
,
indicating
that
the
trigger
and
square
wave
signals
are
locked
.
If
Q1842
or
Q1840
conduct
,
the
current
through
R1836
is
diverted
from
Q1834
and
the
out
put
goes
low
.
The
output
from
this
stage
is
fed
to
the
Fre
quency
Control
Logic
gates
,
depicted
on
Diagram
19
.
4-39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix FG 5010 and is the answer not in the manual?

Tektronix FG 5010 Specifications

General IconGeneral
BrandTektronix
ModelFG 5010
CategoryPortable Generator
LanguageEnglish

Related product manuals