M
Ü’
Ü’
П
П
1
П
n
C
C
POWER
-
ON
SEQUENCES
AND
DEFAULT
SETTINGS
Each
time
power
is
applied
to
the
FG
5010
,
the
internal
microprocessor
performs
a
self
-
test
diagnostic
routine
to
check
the
instrument
RAM
and
ROM
functionality
.
If
no
RAM
or
ROM
error
is
found
,
the
microprocessor
performs
further
routines
that
check
the
functionality
of
other
instru
ment
hardware
.
Functional
groups
of
circuits
checked
in
clude
the
following
:
Trigger
/
Gate
Control
Logic
Period
Measurement
Counters
and
Logic
Low
Frequency
Generator
Counters
Frequency
Range
Control
Burst
Counters
If
a
RAM
or
ROM
error
is
found
,
an
error
code
will
be
displayed
on
the
front
panel
readout
.
In
this
error
state
,
the
FG
5010
will
not
respond
to
input
from
the
front
panel
or
the
IEEE
-
488
bus
interface
.
Internal
errors
detected
after
the
RAM
and
ROM
tests
have
been
completed
successfully
will
be
reported
at
the
front
panel
and
over
the
IEEE
-
488
bus
.
In
this
error
state
,
the
FG
5010
will
respond
to
input
and
will
attempt
to
operate
despite
the
error
.
An
error
code
may
be
removed
from
the
display
by
pressing
the
front
panel
INST
ID
button
,
by
starting
a
numeric
entry
,
by
incrementing
the
selected
parameter
,
by
pressing
the
CLEAR
button
,
or
by
a
transition
into
the
remote
state
(
REMS
)
.
When
the
self
-
test
has
been
completed
,
the
FG
5010
en
ters
the
local
state
(
LOCS
)
and
assumes
the
following
de
fault
settings
:
FREQ
AMPL
OFFS
PHAS
SYM
NBUR
FUNC
MODE
HOLD
SLOPE
GATE
OUT
COMP
AM
FM
VCF
PLI
Header
REV
JUL
1982
Argument
1.000
kHz
0.5
V
0.0
V
°
50
%
10
SINE
CONT
OFF
POS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
DT
USER
RQS
Header
Programming
-
FG
5010
Argument
The
SRQ
line
on
the
IEEE
-
488
bus
is
also
asserted
un
less
the
bus
address
switch
is
set
to
31
(
Ignore
Bus
Com
mands
)
.
If
the
FG
5010
is
polled
by
the
controller
,
the
status
byte
returned
will
be
65
(
Power
-
On
SRQ
)
if
the
busy
bit
is
false
,
or
81
(
65
+
16
)
if
the
busy
bit
is
true
.
OFF
OFF
ON
APPLICATIONS
Talker
Listener
Programs
The
following
sample
programs
allow
a
user
to
send
any
of
the
commands
listed
in
the
Functional
Command
List
and
to
receive
the
data
generated
.
Talker
Listener
Program
For
4050
-
Series
Controllers
100
REM
FG5010
TALKER
/
LISTENER
PROGRAM
110
REM
FG5010
BUS
ADDRESS
=
24
.
120
INIT
130
W
=
24
140
ON
SRQ
THEN
290
150
DIM
R
$
(
380
)
160
PRINT
"
ENTER
COMMAND
(
S
)
,
MESSAGE
(
S
)
:
"
;
260
INPUT
@W
:
R
$
270
PRINT
R
$
280
GO
TO
160
170
INPUT
A
$
180
PRINT
@W
:
A
$
190
REM
CHECK
FOR
QUERIES
200
IF
POS
(
A
$
,
"
?
"
,
1
)
<
>
THEN
260
210
REM
CHECK
FOR
SEND
220
IF
POS
(
A
$
,
"
SEND
"
,
1
)
<>
THEN
260
230
REM
CHECK
FOR
TEST
240
IF
POS
(
A
$
,
"
TEST
"
,
1
)
=
THEN
260
250
GO
TO
160
330
INPUT
@W
:
E
$
340
PRINT
"
SRQ
OCCURRED
350
PRINT
S
;
" "
;
E
$
360
RETURN
290
REM
THIS
PROGRAM
FOR
ONE
ADDRESS
ONLY
300
REM
(
SRQ
INTERRUPT
HANDLER
)
310
POLL
D
,
S
;
W
320
PRINT
@W
:
"
ERR
?;
"
STATUS
=
*
;
S
3-33