EasyManuals Logo

Tektronix FG 5010 User Manual

Tektronix FG 5010
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Programming
-
FG
5010
Table
3-1
(
cont
)
Abnormal
Event
Internal
Errors
(
300
series
) (
cont
)
No
signal
detected
from
Loop
1
board
Inadequate
frequency
range
(
2
kHz
range
)
Inadequate
frequency
range
(
20
kHz
range
)
Inadequate
frequency
range
(
200
kHz
range
)
Inadequate
frequency
range
(
2
MHz
range
)
Inadequate
frequency
range
(
20
MHz
range
)
Burst
counter
fault
Faulty
RAM
found
(
U1400
)
Faulty
RAM
found
(
U1500
)
Faulty
RAM
found
in
MPU
chip
ROM
placement
error
at
ad
dress
A000
ROM
placement
error
at
ad
dress
C000
ROM
placement
error
at
ad
dress
E000
ROM
checksum
error
at
ad
dress
A000
ROM
checksum
error
at
ad
dress
C000
ROM
checksum
error
at
ad
dress
E000
Error
Query
Serial
Poll
Response
Responseª
System
Events
(
400
series
)
Power
on
User
request
(
via
front
panel
INST
ID
button
)
327
3-32
328
329
330
331
332
333
340⁰
341b
350⁰
370⁰
372⁰
374b
390⁰
392⁰
394b
401
403
Device
Dependent
Events
(
700
series
)
Generator
went
out
of
phase
lock
Generator
went
into
phase
lock
731
732
99
99
99
99
99
99
99
65
67
202
206
"
If
the
FG
5010
is
busy
,
it
returns
a
decimal
number
that
is
16
higher
than
the
listed
number
.
"
Front
panel
display
only
.
If
there
is
more
than
one
event
to
be
reported
,
the
instru
ment
continues
to
assert
SRQ
until
it
reports
all
events
.
(
SRQ
"
stacking
"
consists
of
reporting
only
the
latest
event
of
each
priority
level
.
)
Each
event
is
automatically
cleared
when
it
is
reported
via
Serial
Poll
.
The
Device
Clear
(
DCL
)
interface
message
may
be
used
to
clear
all
events
except
Power
-
On
.
Commands
are
provided
to
control
the
reporting
of
some
individual
events
and
to
disable
all
service
requests
.
For
ex
ample
,
the
User
Request
command
(
USER
)
provides
indi
vidual
control
over
the
reporting
of
the
user
request
event
that
occurs
when
the
front
panel
INST
ID
button
is
pressed
.
The
Request
for
Service
command
(
RQS
)
controls
whether
the
instrument
reports
any
events
with
SRQ
.
RQS
OFF
inhibits
all
SRQ's
.
When
RQS
is
OFF
,
the
ERR
query
allows
the
controller
to
find
out
about
events
without
first
performing
a
Serial
Poll
.
With
RQS
OFF
,
the
controller
may
send
the
ERR
query
at
any
time
and
the
instrument
will
return
an
event
waiting
to
be
reported
.
The
controller
can
clear
all
events
by
sending
the
ERR
query
until
a
zero
(
)
code
is
returned
,
or
clear
all
events
except
Power
-
On
through
the
DCL
interface
message
.
With
RQS
OFF
,
the
controller
may
perform
a
Serial
Poll
,
but
the
Status
Byte
contains
only
Device
Dependent
Status
information
.
With
RQS
ON
,
the
STB
contains
the
class
of
the
event
and
a
subsequent
error
query
returns
additional
information
about
the
previous
event
reported
in
the
STB
.
Sending
Interface
Control
Messages
Interface
messages
and
the
effects
of
those
messages
on
the
FG
5010
interface
functions
are
defined
in
IEEE
Stan
dard
488-1978
.
Abbreviations
from
that
standard
are
used
in
this
description
of
the
effects
on
instrument
operation
.
NOTE
These
commands
are
for
TEKTRONIX
4050
-
Series
controllers
,
but
are
representative
of
those
for
other
controllers
.
Bus
interface
control
messages
are
sent
as
low
-
level
commands
through
the
use
of
WBYTE
controller
com
mands
.
Refer
to
070-2056-01
4050
-
Series
Graphic
System
Reference
Manual
for
RBYTE
controller
commands
.
Higher
level
commands
are
also
available
for
the
user
.
For
the
fol
lowing
commands
,
A
32
plus
the
instrument
address
and
B
64
plus
the
address
.
=
Listen
(
MLA
)
Unlisten
(
UNL
)
Talk
(
MTA
)
Untalk
=
Untalk
-
Unlisten
Device
Clear
(
DCL
)
Selective
Device
Clear
(
SDC
)
Go
To
Local
(
GTL
)
Remote
with
Lockout
(
RWLS
)
Local
Lockout
(
LLO
)
Group
Execute
Trigger
<
GET
>
Serial
Poll
Enable
(
SPE
)
Serial
Poll
Disable
(
SPD
)
WBYTE
@A
:
WBYTE
@
63
:
WBYTE
@
B
:
WBYTE
@
95
:
WBYTE
@
63
,
95
:
WBYTE
@
20
:
WBYTE
@A
,
4
:
WBYTE
@A
,
1
:
WBYTE
@
A
,
17
,
63
:
WBYTE
@
17
:
WBYTE
@A
,
8
:
WBYTE
@
24
:
WBYTE
@
25
:
REV
JUL
1982
U
U
U
U
C
U
U
U
L

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix FG 5010 and is the answer not in the manual?

Tektronix FG 5010 Specifications

General IconGeneral
BrandTektronix
ModelFG 5010
CategoryPortable Generator
LanguageEnglish

Related product manuals