Press
the
INCREMENT
pushbutton
for
an
ampli
tude
of
6.34
V.
h
.
ADJUST
R1033
,
Sine
Input
Offset
,
and
R1022
,
Sine
Drive
,
for
a
distortion
reading
near
the
previous
distor
tion
reading
.
i
.
INTERACTION
-
Repeat
these
adjustments
at
6.32
V
and
6.34
V
for
best
compromise
.
j
.
Press
the
following
buttons
in
the
order
listed
:
(
PARAMETER
)
k
.
ADJUST
R1500
,
Offset
and
R1600
,
Amplitude
,
on
the
A70
Loop
2
board
,
for
minimum
distortion
.
FREQ
2
ENTER
NOTE
The
settings
of
the
Sine
Input
Offset
and
Sine
Drive
controls
may
be
compromised
to
bring
the
sine
distor
tion
to
<
0.5
%
below
200
Hz
only
if
necessary
;
then
repeat
step
23
.
I.
Disconnect
the
distortion
analyzer
from
the
front
-
panel
OUTPUT
connector
.
leave
the
Loop
1
board
on
the
board
extender
.
24.
Adjust
Sine
Ampl
and
Sine
Offset
(
Sine
Shaper
,
A80
)
a
.
Press
the
following
buttons
in
the
order
listed
:
(
PARAMETER
)
(
FUNCTION
)
(
MODE
)
(
PARAMETER
)
REV
JUL
1982
FREQ
1
EEX
3
ENTER
SINE
CONT
AMPL
2
ENTER
(
PARAMETER
)
OFFSET
ENTER
Internal
Adjustment
Procedure
-
FG
5010
b
.
Connect
the
differential
comparator
oscilloscope
to
the
front
-
panel
OUTPUT
connector
.
c
.
ADJUST
-
R1223
,
Sine
Ampl
,
and
R1239
,
Sine
Off
set
,
for
positive
and
negative
peaks
of
+
and
-10.0
V.
f
.
Remove
these
connections
for
the
next
step
.
25.
Adjust
Phase
Lock
Phase
(
Loop
1
,
A60
)
a
.
Set
Power
off
.
Move
P1121
to
NORM
on
CPU
.
Set
Power
on
.
b
.
Connect
a
1
kHz
squarewave
generator
set
to
+
and
-
1
V
to
the
front
-
panel
TRIG
/
GATE
IN
connector
and
the
counter
B
channel
.
See
Fig
.
6-1
.
c
.
Adjust
the
external
generator
for
a
squarewave
with
a
period
of
1000
µs
using
the
counter
and
sufficient
amplitude
to
trigger
the
FG
5010
.
d
.
Connect
the
front
-
panel
TRIG
OUTPUT
connector
to
the
counter
A
channel
.
e
.
Press
the
following
buttons
in
the
order
listed
:
(
MODE
)
PH
LOCK
9
ENTER
f
.
Set
the
counter
to
read
time
A
to
B.
Set
CH
A
and
CH
B
to
trigger
on
positive
slope
.
g
.
ADJUST
-
R1052
,
Phase
Offset
,
until
the
leading
edge
of
the
TRIG
OUTPUT
waveform
leads
the
input
signal
by
250
μs
.
h
.
Change
the
input
to
the
counter
A
channel
to
the
ex
ternal
generator
and
the
counter
B
channel
input
to
the
TRIG
OUTPUT
connector
.
6-9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix FG 5010 and is the answer not in the manual?

Tektronix FG 5010 Specifications

General IconGeneral
BrandTektronix
ModelFG 5010
CategoryPortable Generator
LanguageEnglish

Related product manuals