Troubleshooting
TDS 420A, TDS 430A & TDS 460A Service Manual
6-77
Troubleshooting Equipment
Equipment listed in Tables 4--1, 5--3, 6--4, and 6--8 of this manual, or equivalent
equipment, may be useful while troubleshooting this oscilloscope. Construction
of and set-up of other troubleshooting equipment are also listed in this section.
Table 6- 8: Troubleshooting Test Equipment, Fixtures, and Supplies
Item Number and
Description
Minimum Requirements Example Purpose
1. Console Port Tektronix part number
174-2613-00
Tektronix part number
174--2613--00 (see Figure 6--30
on page 6--79)
Troubleshooting using the
Console Port
2. Comput er IBMR PC compatible Troubleshooting using the
Console Port
3. Extensi on cable Console port to computer
connection
Troubleshooting using the
Console Port
4. Telecommunication
software
RS-232, 9600 baud Cross TalkR Troubleshooting using the
Console Port
5. Oscilloscope 200 MHz (for the TDS 420A) or
400 MHz (for the TDS 430A
and TDS 460A) digitizing oscil-
loscope
TEKTRONIX TDS 430A,
TDS 420A, or TDS 460A
General troubleshooting
The console port allows you to see detailed diagnostic messages when faults in
the oscilloscope prevent display of the normal diagnostics. Use this procedure to
set up the console port:
NOTE. You may need a DB-9 to DB-25 adaptor, null modem adaptor, gender
changer adaptor, and an extension cable to connect the console port to your
personal computer (see Figure 6--30 on page 6--30). Using Table 6--9 as a guide
you can wire a cable to take the place of a DB9 to DB25 adaptor, null modem
adaptor, gender changer, and an extension cable.
1. Equipment required: Console port (Item 1), a personal computer or
terminal (Item 2), and telecommunication (terminal) software (Item 4) for
the personal computer. Your personal computer may also require a DB-9 to
DB-25 adaptor, null modem adaptor, gender changer adaptor, and an
extension cable to connect the console port to your personal computer (see
Figure 6--30 on page 6--79).
2. Prerequisites: Power off the oscilloscope.
Console Port Set Up