Specifications
1-22
TDS7104 & TDS7054 Service Manual
Table 1- 11: Certifications and compliances (cont.)
Category Standards or description
EC Decl aration of Conformity --
Low Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the
European Union:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
EN 61010-1/A2:1995 Safety requirements for electrical equipment for measurement
control and laboratory use.
U.S. Nati onally Recognized
Test ing Laboratory Listing
UL3111-1, First Edition Standard for electrical measuring and test equipment.
Canadian Certification CAN/CSA C22.2, Safet y requirements for electrical equipment for measurement,
No. 1010.1-92 control, and laboratory use.
Additional Compliance IEC61010-1 Safety requirements for electrical equipment for measurement,
control, and laboratory use.
Installation (Overvoltage)
Category Definition
Termi nals on this product may have different installation (overvoltage) category designations. The
installation categories are:
CAT III Distribution-level mai ns (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.
CAT II Local-level mai ns (wall sockets). Equipment at this level includes appliances, portable
tools, and similar products. Equipment is usually cord-connected.
CAT I Secondary (signal level) or battery operated circuits of electronic equipment.
Pollution Degree Defini tion A measure of the contaminates that could occur in the environment around and within a product.
Typically the internal environment inside a product is considered to be the same as the external.
Products should be used only in the environment for which they are rat ed.
Pollution Degree 2 Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivit y that is caused by condensation must be
expected. This location is a typical office/home environment.
Tem porary condensation occurs only when the product is out of
service.
Safety Certification Compliance
Equipment Type Test and measuring
Safety Class Class 1 (as defined in IEC 1010-1, Annex H) -- grounded product
Pollution Degree Pollution Degree 2 (as defined in IEC 1010-1). Note: Rated for indoor use only.

Table of Contents

Other manuals for Tektronix TDS6000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS6000 Series and is the answer not in the manual?

Tektronix TDS6000 Series Specifications

General IconGeneral
BrandTektronix
ModelTDS6000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals