EasyManua.ls Logo

Tektronix TDS3054 Service Manual

Tektronix TDS3054
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Service Manual
TDS3000 Series
Digital Phosphor Oscilloscopes
071-0382-01
This document supports firmware version 2.00
and above.
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS3054 and is the answer not in the manual?

Tektronix TDS3054 Specifications

General IconGeneral
Bandwidth500 MHz
Channels4
Sample Rate5 GS/s
Vertical Resolution8 bits
Input CouplingAC, DC, GND
Trigger ModesAuto, Normal, Single
Display TypeColor LCD
Timebase Accuracy± 50 ppm
Operating Temperature0 °C to +50 °C
Vertical Sensitivity1 mV/div to 10 V/div
Input Impedance1 MΩ
Trigger TypesEdge, Pulse, Video, Logic

Summary

General Safety Summary

Safety Precautions

General precautions to avoid injury and product damage during operation.

Handling Hazardous Conditions

Precautions for safe operation in various environmental and operational conditions.

Service Safety Summary

General Service Safety Guidelines

Essential safety rules for performing service procedures on the instrument.

Specifications

General and Input Specifications

Conditions for meeting specs, typical vs. guaranteed values, and input ratings.

Vertical and Horizontal Specifications

Specifications for vertical scale, bandwidth, and horizontal acquisition parameters.

Trigger, Display, and I/O Specifications

Specs for trigger sensitivity, display characteristics, and I/O ports.

Operating Information

Theory of Operation

Performance Verification

Self Test and DC Voltage Accuracy

Procedures for performing the self-test and checking DC voltage measurement accuracy.

Bandwidth, Trigger, and Time Base Accuracy Tests

Procedures for testing bandwidth, trigger sensitivity, and time base accuracy.

Adjustment Procedures

Factory Adjustment Execution

Step-by-step guide to perform the factory calibration procedure using the CAL switch.

Maintenance

Troubleshooting Guide

Required tools and initial steps for troubleshooting instrument failures.

Power-Related Troubleshooting

Flowcharts for troubleshooting power-on issues and power distribution problems.

Module-Specific Troubleshooting

Step-by-step procedures for troubleshooting specific modules like battery, front panel, and main board.

Related product manuals