Teledyne 311 User Manual

Teledyne 311
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
+05647%6+10/#07#.
(14
64#%'1:;)'0#0#.;<'4
/1&'.
6'.'&;0'#0#.;6+%#.+05647/'065
%*'56076564''6
%+6;1(+0&7564;%#
6'.'2*10' 


(#: 

9GDwww.teledyne-ai.com
Question and Answer IconNeed help?

Do you have a question about the Teledyne 311 and is the answer not in the manual?

Teledyne 311 Specifications

General IconGeneral
BrandTeledyne
Model311
CategoryAnalytical Instruments
LanguageEnglish

Summary

Safety Warnings

Skin Contact

Flush contact area with cold water for several minutes, seek medical attention.

Eye Contact

Flush with cold water for at least 15 minutes, seek immediate medical attention.

If Swallowed

Drink milk or milk of magnesia, seek immediate medical attention.

If Inhaled

Move to fresh air, use artificial respiration or oxygen if needed, seek medical attention.

Introduction

1.1 Description

Overview of the Model 311 trace oxygen analyzer, its purpose and portability.

1.2 Method of Analysis

Details the electrochemical fuel cell principle used for oxygen measurement.

Outstanding Features

1.3.1 Micro-Fuel Cell

Sealed, disposable transducer with no electrolyte to change or electrodes to clean.

1.3.2 Reliable Calibration

Allows calibration using atmospheric air, the most economical standard.

1.3.3 Integral Power Supply

Internal rechargeable NiCad batteries provide up to 35 days of operation per charge.

1.3.4 Accuracy and Response

Specifications for measurement accuracy and gas response times.

1.3.5 Compact Packaging

Describes the instrument's durable aluminum case and carrying features.

Supporting Equipment and Services

2.1 Sampling Equipment

Guidance on selecting and using sampling equipment for accurate measurements.

2.2 Power Service

Information on power requirements for battery recharging.

Operation

3.1 Introduction

Initial setup and readiness of the Model 311 for immediate use.

3.2 Calibration

Discusses calibration frequency and prerequisites for accurate readings.

Calibration Procedures

3.2.1 Air Calibration Procedure

Step-by-step guide for calibrating the analyzer using ambient air.

Advanced Operation

3.2.2 Standard (Span) Gas Calibration

Optional calibration method using a known concentration span gas.

3.3 Positive Pressure Sampling

Correct procedure for connecting to positive pressure sample sources.

Sampling Methods

3.4 Atmospheric Pressure Sampling

Techniques for sampling gases at atmospheric or negative pressure using a pump.

Maintenance

4.1 Battery Power Supply Service

Instructions for proper battery recharging and safety precautions.

4.2 Routine Maintenance

Minimal routine maintenance required beyond battery charging.

4.3 Cell Replacement

Detailed steps for replacing the Micro-Fuel Cell and troubleshooting calibration issues.

Cell Warranty and Handling

4.4 Cell Warranty

Information on the warranty period, storage, and handling of the cell.

Transducer Compensation

Leak Testing

Product Specification Data

Recommended Spare Parts List

Drawing List