21
The unit only alarms with phone calls:
Set the GSM Short Message Service phone number to
directory memory cell 0.
Alarm is also sent as a text message.
Alarm is sent every time monitoring is switched on:
Check the wires of the alarming sensor. There is nothing in the “alarms” field
when asked with command #?
No changes in relays:
The unit might be in programming mode, switch the unit to
normal mode.
Insert your number in the phone directory. Only the
commands sent from known phone numbers are executed.
A confirmation message is returned.
Verify that the syntax of the command is correct.
Verify that the user has adequate permissions.
Heating does not go on:
If you have Alde 3010, make sure remote control is
activated.
Heating goes on after sending the
command.
Check the syntax of the command, for example, #HEATING
ON.