EasyManua.ls Logo

Teletek electronics ECLIPSE 8 - Page 42

Teletek electronics ECLIPSE 8
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ECLIPSE 8/16/32/99 Series – User Operation Manual
42
11

11
Activated zone with “24h Burglary” AUX attribute
12

12
Restored zone with “24h Burglary” AUX attribute
13

13
Activated zone with AUX “AC Loss” attribute
14

14
Restored zone with AUX “AC Loss” attribute
15

15
Activated zone with AUX “Battery Low” attribute
16

16
Restored zone with AUX “Battery Low” attribute
17

17
Activated zone with AUX “Water leakage” attribute
18

18
Restored zone with AUX “Water leakage” attribute
19

19
Activated zone with AUX “GAS Detector” attribute
20

20
Restored zone with AUX “GAS Detector” attribute
21

21
Activated zone with AUX “GSM Link Trouble” attribute
22

22
Restored zone with AUX “GSM Link Trouble” attribute
23

23
Activated zone with AUX “GAS Trouble” attribute
24

24
Restored zone with AUX „GAS Trouble” attribute
25

25
Activated zone with AUX “High temperature” attribute
26

26
Restored zone with AUX “High temperature” attribute
27

27
Activated zone with AUX “Low temp” attribute
28

28
Restored zone with AUX “Low temp” attribute
29

29
Activated zone with AUX “Loss of heat” attribute
30

30
Restored zone with AUX “Loss of heat” attribute
31

31
Activated zone with “Write to LOG”
(1)
attribute
32

32
Restored zone with “Write to LOG”
(1)
attribute
33

33
Zone Bypass
34

34
Zone Bypass restore
35

35
Quick arming – FULL ARM
36

36
Quick arming – STAY ARM
37

37
Quick arming – SLEEP ARM
38

38
Arming with user code - FULL
39

39
Arming with user code - STAY
40

40
Arming with user code - SLEEP
41

41
Disarming with user code
42

42
Remote arming - FULL
43

43
Remote arming - STAY
44

44
Remote arming - SLEEP
45

45
Remote disarming
46

46
Arming with key switch - FULL
47

47
Arming with key switch - STAY
48

48
Arming with key switch - SLEEP
49

49
Disarming with key switch
50

50
FULL Arming on Timeslot
51

51
STAY Arming on Timeslot
52

52
Disarming on Timeslot
53

53
FULL Arming on “no movement”
54

54
STAY Arming on “no movement”
55

55
Bypass of zone with FORCE attribute when arming
56

56
Debypass of zone with FORCE attribute when disarming
57

57
Arm Delay on Timeslot
58

58
Ambush code entered
59

59
Medical panic alarm sent from keyboard
60

60
Medical panic alarm from keyboard restored
61

61
Police panic alarm sent from keyboard
62

62
Police panic alarm from keyboard restored
63

63
Fire panic alarm sent from keyboard
64

64
Fire panic alarm from keyboard restored

65
Keyboard blocking

66
Entry in Engineer programming menu

67
Exit from Engineer programming menu

68
Entry in Remote programming mode

69
Exit from Remote programming mode

70
Periodical test

Table of Contents