Do you have a question about the Teletek electronics MAG8 and is the answer not in the manual?
Foreign customers have the same guarantee rights as Bulgarian customers, excluding duties.
Process for obtaining guarantee service, including RAN form and technical documentation.
Circumstances that invalidate the guarantee, such as improper use or damage.
Defines limitations on manufacturer liability and exclusion of implicit guarantees.
Details on repairing or replacing products outside the warranty period and associated costs.
Details the different operating modes of the MAG8 panel and their corresponding LED indications.
Explains the meaning of LED indicators for the status of zones 1 through 8.
Describes the LED indicators for various technical faults within the system.
Details the LED indicators that show the overall system status.
Explains the function of each button on the MAG8 panel for programming and operation.
Describes the switch used to change between Access Levels 1 and 2.
Guidance on selecting the panel location and preparing the housing for mounting.
Instructions for routing cables, connecting mains supply, and wiring safety.
Steps for fitting EOL modules and connecting the battery.
Ensuring wiring integrity, including insulation to earth, before panel connection.
Steps for powering up the panel and identifying initial faults.
Instructions for fitting EOL modules to zone terminals, observing polarity.
Connecting zone circuits to the panel and initial testing for faults.
Procedure for fitting EOL resistors to the last sounder on each circuit.
Connecting sounder circuits to the panel and testing their operation.
Details on using changeover contacts for low voltage devices and a mains power warning.
Connecting a switch for class change and its effect on sounder operation.
Describes the repeater panel's function and how to connect it to the master panel.
Steps for configuring master and slave panels for repeater operation.
Procedure to set the jumper for master panel mode.
Steps to set the jumper for repeater (slave) panel mode.
Instructions to remove jumpers for single panel mode.
Procedure to set the jumper for wireless receiver mode.
Explains sounder delay activation, panel fire LED indication, and silencing.
Guide to setting sounder delay intervals using jumpers.
Purpose of double action mode to avoid false alarms by waiting for repeat signals.
Enables instantaneous sounder and LED activation for specific zones.
Describes different sound signals like short beeps, continuous, and interrupted beeps.
Step-by-step guide to enable or disable individual zones on the panel.
Instructions for enabling or disabling sounders, including LED indications.
Details the 'One Man' test mode for checking detector efficiency.
Provides visual examples for disabling zones and sounders.
Details on the number of zones and detectors per zone.
Defines current thresholds for fault, normal, and fire alarm conditions.
Specifications for main and standby power, and current draw.
Details on sounder circuits and fault/fire relay outputs.
Specifications for auxiliary output, cable size, and operating environment.
Lists compatible modules like Relay and Log Memory modules.
| Display Type | LCD |
|---|---|
| Input Voltage | 220VAC |
| Zones | 8 |
| Communication | PSTN |
| Backup Battery | 7Ah |
| Dimensions | 80mm |