Socket Last Closure command (AT#SLASTCLOSURE) displays zero when socket
is closed.
HTTP methods HEAD, DELETE, PUT are NOT supported
#HTTPSND <data_len> parameter supports maximum data length of 2048 characters
#HTTPRING <content-type> parameter is always "text/html; charset=UTF-8"
#SSLSECCFG commands are NOT supported
#SSLSECDATA command supports only CA certificates in “.PEM” format
After terminating #SSLSECDATA command using ESC char, delete certificate
command should be issued
+CCLK command supports local time zone only.