16
4. AVL Parameters ID
When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling
I/O element(s) AVL packet along with GPS information contains current value(s) of enabled I/O
element. List of available CAN data, parameter size, ID and value range you can find in Table 5.
Table 5 ACQUIRED PARAMETRS IO Ids
Property Input Param
index
Size
(Bytes)
Param
IO ID
Measurement
units
a1 Remarks
CAN-CONTROL
Program number
29 4 100 - -
Module ID 30 8 101 - -
Total Mileage 33 4 87 meters 1
Total Mileage (counted) * 34 4 105 meters 1
Fuel Consumed 35 4 83 Ltr * 10 0.1
Fuel Consumed (counted) * 36 4 107 Ltr * 10 0.1
Fuel Level [%] 37 1 89 % 1
Fuel Level [liters] 38 2 84 Ltrs * 10 0.1
Engine RPM 42 2 85 - 1
Engine Temperature 44 1 115 °C x 10 0.1 signed
Accelerator Pedal Position 45 1 82 % 1
Vehicle Speed 46 1 81 km/h 1
Control State Flags 52 4 123 - -
Security State Flags 61 8 132 -
Battery Level (percent) 81 1 152 % 1
NOTE:
„Total Fuel Used“ is sent to server multiplied by 10.
Example: if value was 150.5 liters, „1505“ will be sent to server.
* - Fuel consumed (counted), Total mileage (counted), Engine Work Time (counted) are
parameters, which are counted after CAN-CONTROL is connected to CAN bus.