11
3.4.4 FMB1YX IO Elements
3.4.4.1 CAN Adapter Mode
Sets LVCAN mode: 0 – Auto Detect, 1 – LV-CAN200, 2 – ALL-CAN300, 3 - CAN-CONTROL.
3.4.4.2 Send data with 0, if ignition is off (ID = 45001)
This parameter enables/disables data sending with 0 value, if ignition is off. 0 – Disable, 1 –
Enable.
3.4.4.3 Program Number (ID = 45002)
Sets LVCAN Program number.
3.4.4.4 1
st
LVCAN property parameter priority (ID=45100)
Parameter defines LVCAN property type of priority: 0 is disabled, 1 – low, 2 – high, 3 - panic.
3.4.4.5 1
st
LVCAN property parameter operand (ID=45101)
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0 2 0 Send data with 0, if ignition is off
(ID = 45001)
Program Number (ID = 45002)
Uint8
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0 1 0 LVCAN Mode (ID = 45000)
Program Number (ID = 45002)
Uint8
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0 999 0 LVCAN Mode (ID = 45000)
Send data with 0, if ignition is off
(ID = 45001)
Uint16
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0 1 0 LVCAN Mode (ID = 45000)
Program Number (ID = 45002)
Uint8