Questions and Answers

  • J
    Jesse CrawfordAug 17, 2025
    Why my Tennant T17 won't start?
    • R
      rebecca29Aug 18, 2025
      Your Tennant Scrubber might not be starting due to several reasons: the emergency stop button may be activated (turn the button clockwise to reset it), there may be a machine fault detected (refer to the fault indicators or warning codes), the battery could be discharged (charge the battery), the battery cables might be loose (tighten them), or the battery itself could be faulty (replace the battery). In rare cases, there may be an issue with the key switch or control board, in which case you should contact a Tennant service representative.
  • Y
    ycarrollAug 20, 2025
    How to fix poor water pickup with my Tennant T17?
    • K
      Kelsey ArnoldAug 20, 2025
      If your Tennant Scrubber is leaving water behind, it could be due to several reasons. Check the squeegee blades for wear and rotate or replace them if needed. Ensure the squeegee is properly adjusted. The squeegee assembly, vacuum hose, or vacuum fan inlet filter might be clogged, so clean them thoroughly. Also, check for a loose or damaged vacuum hose and secure or replace it. Make sure the tank cover is completely closed and that there are no obstructions. Finally, inspect the seals on the recovery tank and replace them if torn or damaged. Debris caught on the squeegee can also cause this issue; remove any debris you find.
  • J
    Judy MurrayAug 23, 2025
    What to do if my Tennant T17 has little or no solution flow?
    • B
      Belinda DuncanAug 23, 2025
      If your Tennant Scrubber isn't dispensing enough solution, first check if the solution tank is empty and fill it if necessary. Make sure the solution flow is turned on. If the issue persists, the solution supply lines may be plugged, requiring you to flush them. Lastly, the solution solenoid might be clogged or stuck, so try cleaning or replacing it.
  • M
    Mrs. Jill WallaceAug 26, 2025
    How to improve the scrubbing performance of my Tennant T17?
    • M
      Misty TaylorAug 26, 2025
      To enhance your Tennant Scrubber's scrubbing, start by removing any debris caught on the scrub brushes. If the problem continues, contact a Tennant representative to ensure you are using the correct detergent and brushes/pads. Replace worn scrub brushes or pads. Reduce the scrub brush down pressure if it seems excessive. Level the scrub head if the brush pressure is uneven. Empty the debris trough if it's full. If you have a cylindrical scrub head, check and replace any broken brush drive belts. Finally, ensure the battery is fully charged until the charger automatically turns off.
  • P
    Phillip YorkAug 27, 2025
    Why won't the vacuum fan turn on in my Tennant T17?
    • J
      Joshua WardAug 27, 2025
      The vacuum fan in your Tennant Scrubber might not turn on if the recovery tank is full; drain the tank. Foam filling the recovery tank can also cause this, so empty the tank. To prevent foam buildup, use less detergent, switch to a different detergent, or use a defoamer.
  • K
    kevin87Aug 30, 2025
    Why does my Tennant T17 Scrubber have reduced run time?
    • L
      Logan BrooksAug 30, 2025
      A reduced run time in your Tennant Scrubber can be caused by a battery that is not fully charged; charge the battery until the charger automatically turns off. It could also be due to a defective battery, which would need to be replaced. The batteries may need maintenance. A faulty battery charger could also be the reason and would need replacing.
  • E
    Elizabeth MorrisSep 1, 2025
    What to do if the ES System on my Tennant T17 Scrubber isn't working?
    • V
      Victoria CollinsSep 1, 2025
      If the ES system on your Tennant Scrubber isn't operating, make sure the ES button is turned on. Check the ES sensor in the tank; it might be dirty or not in the correct position, so clean or reposition it. Also, the ES pump filter could be clogged, requiring cleaning. Ensure the water level in both the recovery and solution tanks is adequate; fill the recovery tank approximately half full and the solution tank completely.
  • J
    Jessica EvansSep 4, 2025
    Why is the high pressure washer on my Tennant T17 Scrubber not working?
    • R
      rileystacySep 4, 2025
      If the high-pressure washer on your Tennant Scrubber isn't working, ensure the parking brake is set. The thermal switch on the high-pressure pump motor may have tripped; allow it to cool down. Check if the solution pump circuit has tripped and reset the circuit breaker if needed. Finally, make sure the switch was not left on when the machine was started; turn it off and then back on.
  • M
    Michael SmithSep 6, 2025
    What does it mean if the warning light is solid red on my Tennant ec?H2O Scrubber?
    • W
      whitney35Sep 7, 2025
      The solid red warning and fault indicator light on your Tennant ec?H2O Scrubber could indicate a defective solution pump, which would need to be replaced. Alternatively, contact a Tennant service representative.
  • W
    Willie ValenzuelaSep 9, 2025
    Why is my Tennant T17 Scrubber's high pressure washer spraying at low pressure?
    • A
      Alicia CalderonSep 9, 2025
      If your Tennant Scrubber's high-pressure washer is spraying at low pressure, check the spray nozzle setting and adjust it as needed. Also, verify the spray pump pressure knob and adjust it accordingly.

Summary

Safety Precautions

Important Safety Instructions

Essential safety guidelines to follow for machine operation and servicing.

Operation

Machine Components

Identification and description of the main parts of the T17 rider scrubber.

Controls and Instruments

Overview of the machine's control panel, buttons, and indicators.

Standard Touch Panel

Detailed explanation of the standard control panel interface and its functions.

Pro-Panel Controls

Detailed explanation of the Pro-Panel interface and its advanced features.

Symbol Definitions

Explanation of various symbols used on the machine's interface and controls.

Operation of Controls - Standard Panel

Step-by-step guide for using controls and indicators on the standard panel.

Operation of Controls - Pro-Panel

Step-by-step guide for using controls and indicators on the Pro-Panel.

How the Machine Works

Explanation of the machine's operational principles and cleaning technologies.

Filling the Solution Tank

Instructions for filling the solution tank for conventional and ec-H2O modes.

ES (Extended Scrub) Mode - Manual Tank Fill

How to fill tanks for the Extended Scrub system.

Scrub Brush Pressure

How to adjust scrub brush pressure for optimal cleaning performance.

Solution Flow

How to adjust the solution flow rate for different cleaning needs.

Draining and Cleaning the Recovery Tank

Daily procedures for draining and cleaning the recovery tank.

Fault Indicators; Warning Codes

Understanding and responding to machine fault and warning indicators.

Options

Information on optional equipment and their operation.

Spray Nozzle (Option)

How to use the spray nozzle for cleaning the machine and surroundings.

High Pressure Washer (Option)

Instructions for operating the optional high pressure washer.

Wet Vacuum Wand (Option)

How to use the optional wet vacuum wand for cleaning hard-to-reach areas.

Live Wand (Option)

Operation of the live wand for picking up dry debris.

Maintenance

Maintenance Chart

Schedule and responsibilities for routine machine maintenance tasks.

Lubrication

Guidelines for lubricating key machine components like steering and drive pivots.

Batteries

Information on battery maintenance, charging, and care for optimal lifespan.

Circuit Breakers, Fuses, and Relays

Location and function of electrical protection devices like breakers and fuses.

Scrub Brushes

Information on checking, replacing, and maintaining scrub brushes and pads.

Squeegee Blades

How to check, rotate, and replace squeegee blades for optimal drying.

Pushing, Towing, and Transporting the Machine

Safe procedures for moving, towing, and transporting the machine.

Machine Jacking

Correct procedures and safety precautions for jacking the machine.

Storage Information

Steps for preparing and storing the machine for extended periods.

Specifications

General Machine Dimensions;Capacities

Key physical dimensions and tank capacities of the machine.

General Machine Performance

Performance metrics like turning radius, travel speeds, and ramp inclines.

Power Type

Details on battery types, electric motors, and charger specifications.

Supervisor Controls

Pro-Panel Supervisor Controls

Features and capabilities for supervisors to configure machine settings.

Entering the Supervisor Mode

Steps to access and log into the supervisor mode for advanced settings.

Adding; Editing Profiles

Creating, modifying, and managing user and supervisor profiles.

Changing the Battery Type

How to set the machine to recognize the correct battery type.

Checklist Setup

Configuring or changing the pre-operation checklist items and intervals.

Programming the Zone Control Buttons

Setting up custom scrubbing/sweeping parameters for zone control buttons.

Setting; Changing the Screen Lock

Configuring the screen lock delay for the operator interface.

Tennant T17 Specifications

General IconGeneral
BrandTennant
ModelT17
CategoryScrubber
LanguageEnglish

Related product manuals