PANEL MONITORING
PANEL MONITORING
- Lifting Conditions % and alarms
Is the control panel informing about safety on the machine?
Yes! It has been designed and its main scope is to check the
machine working conditions, comparing them to the limits
given by the load Tables previously memorised.
1) LCD bar showing the percentage of the load lifted at this moment.
2) Green reference : Safe Zone.
3) Amber reference : Alarm Zone.
(Lifted load higher than 90% of maximum admitted load).
4) Red reference : Shut-off Zone
(Lifted load higher than 100% of maximum admitted load).
5) Green light on : Safe Working
6) Amber light on : Alarm (Buzzer activated = intermittent)
7) Red light on : Dangerous movements shut off
(Buzzer activated = continuous)