November 2021 Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1305686GT Scissor Lifts 31
GS-4046, GS-55
1 Batteries, B5
2 Fuse, F6, 275A
3 Quick disconnect, QD1
GS-69 DC / BE
1 Quick disconnect, QD1
2 Batteries, B5
2 Inspect the battery charger plug and pigtail for
damage or excessive insulation wear.
Replace as required.
Q-3
Check the Module Tray Latch
Components
Genie specifications require that this procedure be
performed quarterly.
Maintaining the module tray latch components in
good condition is essential to good performance
and service life. Failure to detect worn out latch
components may result in module trays opening
unexpectedly, creating an unsafe operating
condition.
1 Inspect each module tray latch and related
components for wear. Tighten any loose
fasteners.
2 Lubricate each module tray latch. Using light
oil, apply a few drops to each of the springs