Do you have a question about the TESTO 316-3 and is the answer not in the manual?
Guidance on reading the manual, warnings, and keeping the document for future reference.
Instructions for safe operation, checking for damage, and avoiding electrical risks.
Description of the testo 316-3 as a leakage detector for refrigeration systems and heat pumps.
Detailed technical specifications including sensor, refrigerants, thresholds, battery life, and operating conditions.
Diagram and labels identifying key components of the testo 316-3 leakage detector.
Instructions for installing the sensor and inserting batteries for initial setup and operation.
Guidance on adjusting the sensitivity levels (HI/LO) for optimal leak detection performance.
Step-by-step procedure for locating refrigerant leaks using the leakage detector.
Instructions on how to clean the instrument housing using a damp cloth and mild cleaning agents.
Procedure for replacing the sensor, including safety precautions and steps.
Instructions for replacing the filter if it becomes clogged with water or oil.
Step-by-step guide for replacing the instrument's batteries.
Common issues, possible causes, and solutions for operating the leakage detector.
List of available replacement parts and accessories with their item numbers.
Guidance on reading the manual, warnings, and keeping the document for future reference.
Instructions for safe operation, checking for damage, and avoiding electrical risks.
Description of the testo 316-3 as a leakage detector for refrigeration systems and heat pumps.
Detailed technical specifications including sensor, refrigerants, thresholds, battery life, and operating conditions.
Diagram and labels identifying key components of the testo 316-3 leakage detector.
Instructions for installing the sensor and inserting batteries for initial setup and operation.
Guidance on adjusting the sensitivity levels (HI/LO) for optimal leak detection performance.
Step-by-step procedure for locating refrigerant leaks using the leakage detector.
Instructions on how to clean the instrument housing using a damp cloth and mild cleaning agents.
Procedure for replacing the sensor, including safety precautions and steps.
Instructions for replacing the filter if it becomes clogged with water or oil.
Step-by-step guide for replacing the instrument's batteries.
Common issues, possible causes, and solutions for operating the leakage detector.
List of available replacement parts and accessories with their item numbers.
| Type | Gas Leak Detector |
|---|---|
| Sensor Type | Heated diode sensor |
| Resolution | 1 ppm |
| Dimensions | 190 x 57 x 42 mm |
| Storage Temperature | -20°C to +60°C |
| Operating Temperature | -10°C to +50°C |
| Measuring Range | 0 to 10, 000 ppm (methane) |
| Accuracy | ±10% of reading |