testo 320 · Flue gas analyzer
Instruction manual
1.888.610.7664 info@Testo-Direct.com
www.Testo-Direct.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TESTO 320 and is the answer not in the manual?

TESTO 320 Specifications

General IconGeneral
Power SupplyRechargeable battery
H2-compensated CO sensorYes
Draft measurementYes
Differential pressure measurementYes
Protection ClassIP40
Measurement ParametersO2, CO, CO2, temperature, draft, differential pressure
O2 Measurement Range0 to 25%
CO Measurement Range0 to 4000 ppm
CO2 Measurement Range0 to 25%
Temperature Measurement Range0 to 600°C
Operating Temperature0 to 50°C
Resolution0.1 °C (temperature), 1 ppm (CO), 0.1% (O2), 0.1% (CO2), 0.01 hPa (differential pressure), 0.01 m/s (flow)
Accuracy±0.2% (O2), ±5 ppm or ±5% of mv (CO)

Summary

Safety and the environment

Ensure safety

Instructions for safe operation, maintenance, and handling of the instrument.

Specifications

Technical data

Detailed technical specifications including certifications and data.

Measurement ranges and resolution

Lists the measuring ranges and resolution for various parameters.

Accuracy and response time

Details the accuracy and response times for different measurement parameters.

Product description

Measuring instrument

Details about the main device, including its front view and keypad.

First steps

Commissioning

Initial setup steps, including charging the battery before first use.

Entering values

Instructions on how to input numerical and text data using list fields or editors.

Using the product

Performing settings

How to configure various instrument settings for optimal operation.

Recalibration/adjustment

Procedure for recalibrating and adjusting CO sensors.

Fuels

How to select and configure fuel types for accurate measurements.

Measuring

Core procedures for taking measurements with the instrument.

Preparing for measurement

Steps to prepare the instrument and system before taking measurements.

Testing for leaks

Procedure to test the measurement system for leaks to ensure accuracy.

Zeroing phases

How to perform gas and draught/pressure zeroing for accurate readings.

Flue gas

Steps for performing a standard flue gas measurement.

Draught measurement

Procedure for measuring draught, including probe positioning.

CO undiluted

How to perform undiluted CO measurements.

Pressure

Procedure for measuring pressure, including safety warnings.

Differential temperature

How to measure differential temperature using the appropriate set.

O2 air

How to perform O2 air measurements with the correct probe.

Gas flow rate

How to measure gas flow rate, noting fuel type availability.

Oil flow

How to measure oil flow, noting fuel type availability.

Ambient CO

How to perform ambient CO measurements, noting probe requirements and influences.

CO2 ambient

How to perform ambient CO2 measurements, noting probe and pressure requirements.

Leak detection

Procedure for gas leak detection, noting probe and country availability.

Maintaining the product

Replacing the rechargeable battery

Step-by-step guide to replace the instrument's rechargeable battery.

Replacing sensors

Procedure for replacing sensors in the instrument.

Recalibrating/adjusting sensors

Procedure for recalibrating and adjusting CO sensors.

Tips and assistance

Updating the instrument software

Instructions for downloading and updating the instrument's firmware.

Related product manuals