Instruction manual en
testo 340
Flue gas analyser

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TESTO 340 and is the answer not in the manual?

TESTO 340 Specifications

General IconGeneral
CO measurement range0 to 10, 000 ppm
NO measurement range0 to 3, 000 ppm
NO2 measurement range0 to 500 ppm
SO2 measurement range0 to 5, 000 ppm
Resolution CO1 ppm
Resolution NO1 ppm
Resolution SO21 ppm
Resolution H21 ppm
Resolution Differential Pressure0.01 hPa
Resolution Flow Velocity0.1 m/s
Resolution Temperature0.1 °C
Power SupplyRechargeable battery
Protection ClassIP40
Measurement ParametersO2, CO, NO, NO2, SO2, CO2, CxHy, Temperature, Draft, Pressure
O2 measurement range0 to 25%
Temperature measurement range-20 to 1, 200 °C
Resolution CO20.1%
Accuracy CO±5 ppm or ±5% of reading
Accuracy NO±5 ppm or ±5% of reading
Accuracy NO2±5 ppm or ±5% of reading
Accuracy SO2±5 ppm or ±5% of reading
Accuracy O2±0.2%
Accuracy CO2±0.5%
Accuracy H2±5 ppm
Accuracy Differential Pressure±0.03 hPa
Accuracy Temperature±0.5 °C
DisplayLCD
Operating Temperature-5 to +45 °C
Storage Temperature-20 to +50 °C

Summary

General Notes and Identification

Identification of Symbols

Explains symbols used in the manual for warnings, text, and keys.

Short Form Operating Steps

Describes the short form notation used for operating steps.

Safety Advice

Electrical Hazard Prevention

Warning against measuring on or near live parts to prevent electrical hazards.

Instrument Protection Measures

Instructions for storing the instrument to prevent damage from solvents or desiccants.

Product Safety and Warranty

Guidelines for safe operation and proper handling to maintain warranty.

Correct Disposal Procedures

Information on the proper disposal of rechargeable batteries and the instrument.

Intended Purpose of Testo 340

Application Areas

Describes the professional flue gas analysis tasks for which the testo 340 is intended.

Product Description

Measuring Instrument Overview

Provides a visual overview and identification of the testo 340 measuring instrument's components.

Keypad Functions

Details the functions assigned to each key on the instrument's keypad.

Display Elements

Explains the elements displayed on the instrument's screen, including header and function select views.

Instrument Connections

Identifies and describes the various sockets and connections on the instrument.

Available Interfaces

Details the available interfaces for connecting the instrument to other devices.

Internal Components

Lists and illustrates the internal components of the measuring instrument.

Commissioning the Testo 340

Attaching the Carrying Strap

Instructions on how to attach and secure the carrying strap to the instrument.

Modular Flue Gas Probe

Describes the components and features of the modular flue gas probe.

Operation of the Testo 340

Mains Unit and Battery Management

Information on using the mains unit and handling the rechargeable battery.

Procedure for Changing the Battery

Step-by-step guide for replacing the rechargeable battery in the instrument.

Battery Charging Procedures

Instructions on how to charge the rechargeable battery, both in the instrument and in the charger.

Operation with Mains Unit

Explains how the instrument operates when connected to the mains unit.

Probes and Sensors

Details on probes and sensors, including connection procedures.

Connecting Probes and Sensors

Guidance on correctly connecting flue gas probes and other sensors to the instrument.

Replacing the Probe Module

Instructions for removing and installing a new probe module.

Regular Care and Maintenance

General advice for maintaining the instrument's condition.

Condensate Trap Maintenance

Details on how to check, empty, and maintain the condensate trap.

Particle Filter Check and Replacement

Procedures for inspecting and replacing the particle filter in the flue gas probe.

Basic Operating Steps

Covers fundamental operations like powering on and navigating menus.

Switching the Instrument On

Explains how to power on the testo 340 and what to expect on the display.

Calling Up Functions

Instructions on how to navigate the menus and select specific functions.

Entering Data Values

Describes methods for inputting values using list fields and input editors.

Printing Measurement Data

Instructions on how to print measurement data from the instrument.

Saving Measurement Data

Details on how to save measurement data using the instrument's functions.

Confirming Error Messages

Guidance on how to acknowledge and interpret error messages displayed by the instrument.

Switching the Instrument Off

Procedure for safely powering down the testo 340, noting unsaved data loss.

Memory Management

Covers functions for storing and organizing measurement data.

Folder Management

Information on creating, ordering, and editing folders for data management.

Location Management

Instructions for creating, activating, restoring, deleting, and setting locations.

Measurement Protocols

Details on printing and deleting measurement protocols.

Extras Memory Functions

Describes functions related to displaying, printing, and deleting memory contents.

Instrument Diagnosis

Tools for checking instrument status and troubleshooting issues.

Performing Gas Path Checks

Steps for conducting a gas path check to ensure no leaks in the system.

Viewing Device Errors

How to access and view diagnostic information on device errors.

Viewing Sensor Diagnosis

Procedure for checking the status and diagnosis of individual sensors.

Configuration Settings

Instrument Settings

Allows setting parameters and units for display representation and instrument configuration.

Display Edit Options

Customizing the display by setting parameters, units, and the number of readings shown.

Printer Configuration

Configuration options for setting print text headers, footers, and selecting a printer.

Start Keys Assignment

Assigning functions to the instrument's start screen keys for quick access.

AutoOff Function Settings

Configuring the automatic instrument shut-off feature based on inactivity.

Communication Interface Setup

Setting up communication interfaces like IR, IrDA, and Bluetooth.

Date and Time Settings

Procedure for setting the instrument's current date and time.

Language Selection

Option to select the desired menu language for the instrument.

Sensor Settings

Options for configuring sensor-specific parameters and protection.

Setting NO2 Addition

Adjusting NO2 addition levels and sensor protection settings.

Setting Sensor Protection Thresholds

Configuring sensor protection thresholds to prevent overloads and extend sensor life.

Displaying ppm/hour Counter

Viewing and managing the ppm/hour counter for sensors with exchangeable filters.

Calibration Data and Sensor Status

Accessing calibration data and sensor status information, including graphics.

Sensor Recalibration Procedure

Detailed steps and conditions for recalibrating sensors with test gases.

Fuel Selection and Settings

Options for selecting fuels and adjusting their specific coefficients.

Activating Fuel Type

Process for selecting and activating a specific fuel type for measurements.

Setting Fuel Coefficients

Adjusting fuel-specific coefficients or resetting them to default values.

Measuring Tasks

Zeroing Phases Explanation

Explains ambient air, gas, and draught/pressure zeroing procedures.

Using the Modular Flue Gas Probe

Instructions for checking and aligning the modular flue gas probe.

Configuring Reading Display

Setting up the display to show required parameters and units.

Setting Measurement Location and Fuel

Guidance on selecting the measurement location and fuel before starting measurements.

Flue Gas Measurement Types

Describes the three main flue gas measurement functions and their capabilities.

Measuring Programs

Details on changing, saving, running, and printing flue gas measuring programs.

Draught Measurement Procedure

Instructions for performing draught measurements, including positioning the probe.

Smoke#/HCT Recording

Recording smoke tester numbers and heat carrier temperatures for oil fuels.

Gas Flow Rate Measurement

Procedure for measuring gas flow rate and its related calculations.

Oil Flow Rate Measurement

Instructions for measuring oil flow rate and its associated calculations.

Flow Speed (m/s) Measurement

Measuring flow speed using a Pitot tube and setting relevant parameters.

Pressure Measurement (Ap2)

Performing pressure measurements, including safety warnings for gas heaters.

Burner Control Functionality

Reading status data and malfunction reports from automatic furnaces.

Reading Current Status Data

Displays current data from automatic furnaces using symbols.

Printing Burner Data

Options for printing identification and failure statistic data.

Reading Failure Store

Accessing failure reports stored in the automatic furnace's circular buffer memory.

Transferring Data

Protocol Printer Usage

Instructions for transferring data to a Testo protocol printer via IR or Bluetooth.

Care and Maintenance

Cleaning the Measuring Instrument

Guidelines for cleaning the instrument's housing using appropriate materials.

Replacing Sensors

Step-by-step instructions for replacing sensors, including handling auxiliary circuit boards.

Filter Replacement for Specific Sensors

Procedures for replacing filters in specific sensors, including precautions.

Sensor Recalibration

Reference to the Sensor settings section for recalibration procedures.

Cleaning the Flue Gas Probe

Instructions for cleaning the flue gas probe and its components.

Replacing the Probe Preliminary Filter

Details on how to unscrew and replace the preliminary filter in probe modules.

Replacing the Thermocouple

Step-by-step guide for removing and installing a new thermocouple.

Questions and Answers

Instrument Power Issues Troubleshooting

Troubleshooting common issues related to the instrument powering off or failing to turn on.

Pump Flow Rate Too High Failure

Addresses the 'Pump flow rate too high' failure report and its possible causes.

Printing Not Possible Troubleshooting

Troubleshooting steps for when the instrument cannot print data.

Technical Data

Standards and Tests Compliance

Information on compliance with directives and standards, and product approval status.

Measuring Ranges and Accuracies

Detailed table of measuring ranges, accuracies, and resolutions for various parameters.

Filter Lifetime Information

Information on the expected lifetime of filters for specific sensors.

Other Instrument Specifications

Lists other important instrument characteristics like operating temperature, power, and dimensions.

Bluetooth Option Details

Details regarding Bluetooth functionality, including designation, range, and certifications.

EC Declaration of Conformity

Official declaration confirming the product's compliance with relevant EU directives and standards.

Principles of Calculation

Fuel Parameters Table

Table of fuel-specific parameters used in calculations, including CO2 max and O2 ref.

Calculation Formulae

Presents formulae for calculating various parameters like Poison Index, Excess Air, and Flow speed.

Mass Flow Calculations

Formulae for calculating mass flow rates for CO, NOx, and SO2.

ppm to mg/m3 Conversion

Provides conversion formulae for CO, NOx, and SO2 from ppm to mg/m3.

Recommended Rinsing Times

Accessories and Spare Parts

Modular Flue Gas Probes

Lists various modular flue gas probes with their specifications and article numbers.

Probe Modules and Accessories

Details probe shafts, extension leads, and filter accessories.

Spare Filters Listing

Lists spare filters for specific sensor types.

Other Retrofitting Kits

Lists retrofitting kits for Bluetooth and sensor dilution options.

Additional Accessories

Lists additional accessories such as printers, cables, and software.

Functional Overview

Flue Gas Measurement Tasks

Overview of flue gas measurement tasks and their corresponding call/function paths.

Memory Function Summary

Summary of memory functions including folder and location management.

Display Settings Overview

Overview of settings for the instrument's display configuration.

Sensor Settings Overview

Summary of sensor setting options including NO2 addition and sensor protection.

Recalibration Overview

Overview of the recalibration process for sensors.

Related product manuals