B. Intended purpose
This chapter describes the areas of application for which the measuring instrument is
intended.
The testo 340 is a handheld measuring instrument used in professional flue gas analysis
for:
· Engineers servicing/monitoring industrial combustion plants (process systems, power
stations)
· Emissions inspectors
· Engine manufacturers and operators
· Service engineers/mechanics of burner/boiler manufacturers in the industrial sector
Typical measuring tasks and particular characteristics of the testo 340 include:
· Measurement on industrial engines (CO/NO dilution)
· Measurement on gas turbines (high precision CO and NO plus optional dilution)
· Emissions measurement (integrated flow speed and differential pressure measurement)
testo 340 should not be used:
· for continuous measurements > 2 h
· as a safety (alarm) instrument
The testo 340 with the Bluetooth option may only be operated in countries in which it
is type approved (see Technical Data).
B. Intended purpose
9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 340 and is the answer not in the manual?

TESTO 340 Specifications

General IconGeneral
CO measurement range0 to 10, 000 ppm
NO measurement range0 to 3, 000 ppm
NO2 measurement range0 to 500 ppm
SO2 measurement range0 to 5, 000 ppm
Resolution CO1 ppm
Resolution NO1 ppm
Resolution SO21 ppm
Resolution H21 ppm
Resolution Differential Pressure0.01 hPa
Resolution Flow Velocity0.1 m/s
Resolution Temperature0.1 °C
Power SupplyRechargeable battery
Protection ClassIP40
Measurement ParametersO2, CO, NO, NO2, SO2, CO2, CxHy, Temperature, Draft, Pressure
O2 measurement range0 to 25%
Temperature measurement range-20 to 1, 200 °C
Resolution CO20.1%
Accuracy CO±5 ppm or ±5% of reading
Accuracy NO±5 ppm or ±5% of reading
Accuracy NO2±5 ppm or ±5% of reading
Accuracy SO2±5 ppm or ±5% of reading
Accuracy O2±0.2%
Accuracy CO2±0.5%
Accuracy H2±5 ppm
Accuracy Differential Pressure±0.03 hPa
Accuracy Temperature±0.5 °C
DisplayLCD
Operating Temperature-5 to +45 °C
Storage Temperature-20 to +50 °C

Related product manuals