7 Using the product
43
filling is paused and must be restarted. This prevents overfilling or
incorrect filling.
Before each measurement, check that the refrigerant hoses are in
flawless condition.
The system must be supervised by a competent person throughout the
entire process.
testo 560i and testo Smart Valve are connected via Bluetooth to the
testo Smart App or the testo 570s manifold.
testo 560i and testo Smart Valve are integrated into the refrigerant
circuit.
Two testo 115i are attached and connected via Bluetooth to the testo
Smart App or the testo 570s manifold.
1
Select the required refrigerant on the manifold/app and press
[Menu/Enter] to confirm.
1.1
If necessary, zero sensor on manifold/app [P = 0].
2
In the manifold/app, select the proper
refrigerant and enter the maximum
system charge.