EasyManua.ls Logo

TestPad BTS-2002H - Capacity Test; Parameter Setup for Li-ion; Parameter Setup for NiCd; Test Process Flow

Default Icon
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shenzhen TestPad Electronic Co., Ltd. http://www.test-pad.com
20
Capacity Test
Select Capacity Test from the main menu to set the battery capacity parameters, as shown
below.
Selecting whether to test over-charge/over-discharge
1. Items 1~3 are the same as those on the static parameter setting interface. Refer to Static Test.
2.
Lion
OC/OD
:
For
Li-ion
battery,
select
YES
to
enable
the
over-charge/over-discharge
test.
..................... Selecting whether to discharge
..................... Nickel-Cadmium battery before charging it
3.
If
the
current
battery
type
is
Nickel-Cadmium
battery,
the
fourth
menu
item
is
4.NiCd
PRE_DIS: NO”. Set whether to discharge the Nickel-Cadmium battery before charging it so
as to eliminate the memory effect of the battery and ensure accurate measurement.
4.
If
the
current
battery
type
is
Nickel-Metal
hydride
battery
or
SLA,
the
fourth
menu
item
is
unavailable.
After you pressing ENTER, the tester follows the process below to test the capacity of the battery.
Pre-discharge (if the current battery type is Nickel-Cadmium battery and pre-discharge is enabled)
Fully charge the battery
Over-current test (if the current battery type is Li-ion battery and over-charge test is enabled)
Wait 100 seconds
Fully discharge
Over-discharge test (if the current battery type is Li-ion battery and
over-discharge test is enabled)
End
->1. Pack type: Lion
2. Pack Vol: 3.6V
3. Pack Cap: 500mAH
4.
Lion
OC/OD:
NO
->1. Pack type: NiCd
2. Pack Vol: 3.6V
3. Pack Cap: 500mAH
4. NiCd PRE_DIS: NO