21
615
GB
INSTRUCTIONS
STARTING UP FIRST TIME
1 - REMOVE THE CANVAS FROM THE MINIPOOL
See “Minipool Canvas”.
08:30
3 - POWER UP THE SYSTEM
CAUTION: power up the electrical equipment only
after the minipool has been filled with water.
Position the isolating switch (fitted during installation) to
ON.
Check the smooth operation of the residual current switch,
wired up during preinstallation, by pressing the test button.
The switch should trip.
Reset the switch following the test.
The recirculation pump will start up automatically.
Start up the whirlpool systems by pressing buttons
Pump1 and Pump2 at the control panel.
Open all the jets, checking that there are no water leaks
from the plumbing connections, and that everything
works as it should; the pumps can now be switched off.
4 - WATER TREATMENT
Treat the water using the products supplied by Teuco, as
described in the accompanying manual.
Other equivalent proprietary products can also be used.
Check that the pH value of the water is between 7.2
and 7.6 and the quantity of chlorine between 1 and
1.5 ppm.
The pH value and Chlorine level must be tested
chemically at frequent intervals to guarantee the quality
of the water is properly maintained and ensure correct
operation of the system.
2 - FILL THE MINIPOOL
Fill the pool until the level is high enough to float the
skimmer.
AM
The water put into the pool must be no hotter
than 35 °C.
Caution: If air has accumulated in the system,
the whirlpool may fail to start.
The air must be released by loosening the ring
nuts on the pumps until the the whirlpool or
recirculation circuit comes into operation; the
nuts can then be retightened.

Table of Contents