4
Symptom
Screen blank, raster
unstable, previous
word select error,
keyboard self-test
failure, sync(s)
LED
not
lighted
Sync (S) LED
not
lighted
H-Sync error only
for part 1. Video
bar on screen,
but
raster unstable
Sync error may
cause keyboard self-
test
to
fail; will prob-
ably cause manual
keyboard
to
input
to
fail
Table 2-9. Fault Isolation Procedures for Apparent Timer Problems
Probable Cause
Defective clock
Constant system
reset
Additional symp··
toms needed
Horizontal blanking
flip-flop
or
steering
circuit
Horizontal sync
flip-flop
or
steering logic
Composite sync
flip-flop
or
steering logic
Troubleshooting Procedure
Scope circuit.
-Scope circuit.
Execute
part
1
(El).
Scope circuit.
Scope circuit.
Scope circuit.
Normal Indication
Clock period = 90
.2
nanoseconds at
U40-8.
NRL2=1 at U98-13
HSBQ = 63
.5
µ sec
period.
HSQ = 63.5
µsec
period
See figure 2-7.
If
Abnormal
Trace circuit back from
U40-8. Replace faulty
component(s).
Trace circuit back from
U98-13 until source
of
error
is
found. Replace
faulty component(s).
Trace circuit back from
V504
until fault
is
found. Replace faulty
component(s).
Trace circuit back from
U50-5 until fault
is
found
Replace faulty component(s).
Sync on VSBQ at 050-13.
Trace circuit back from
050-12.
Replace faulty
component(s).