2.
CONFIGURATION
AND
INSTALLATION
This
section
describes
rack
mounting
of
the
2001
computer,
cabling,
and
expansion
module
installation
and
removal.
2.1
Rack
Mounting
The
2001
computer
and
CRT
display
models
1003R, 1004R,
and
1005R
are
designed
to
be
mounted
in
a
19-inch
RETMA
rack
with
ChassisTrak
300-S-120
slides.
Equivalent
slides
from
other
manufacturers
that
have
matching
hole
spacing
and
alignment
may
also
be
used.
The
steps
for
attaching
slides
to
the
displays
and
the
computer
are
the
same.
Mounting
hardware
is
supplied
with
the.
slides.
9~YI!Q~
DO
NOT
attempt
to
mount
the
computer
or
display
by
attaching
these
units
from
the
front
panel
only.
SLIDE
MOUNTING
INSTRUCTIONS
1.
Two
slides
are
required
for
each
chaasis,
one
on
each
side.
Separate
each
slide
into
two
parts.
2.
Select
the
slide
parts
that
have
a
hole
pattern
matching
the
threaded
holes
on
the
computer.
Using
screws
provided,
attach
a
slide
to
right
and
left
sides
of
the
computer
chassis
(5
screws
on
each
side,
the
spring
loaded
stop
mounts
to
the
rear
of
the
computer).
3.
Attach
the
second
part
of
the
slides
to
the
19-
inch
rack.
Position
the
slides
on
the
left
and
right
sides
of
the
rack
and
screw
each
end
of
the
slide
into
the
rack.
4.
Insert
the
computer
into
the
rack
by
mating
the
computer
slides
with
the
rack
slides.
Make
sure
that
the
computer
is
level
and
properly
aligned
when
it
slides
onto
the
rack.
5.
Push
the
computer
completely
onto
the
rack.
Secure
the
computer
front
panel
into
the
rack
using
4
screws
(8
screws
on
monitors).
6.
Repeat
this
procedure
to
rack
mount
the
CRT
display.
Preliminary
AT
Users
Manual
3
11/26/86