Premier Series User Guide Overview
INS221 3
LED Indicators
Five LED indicators have been provided to indicate the status of the system.
LED Status Meaning
Power On AC mains is present on the control panel
Flashing AC Mains is not present, the control panel is running on the standby battery
Service On The system requires attention, contact your installer
Off The system does NOT require attention
Ready On All zones are secure and the system is ready to be armed
Off One or more zones are active
Flashing The system has zones (with the ‘Force Omit’ attribute) that are active
Info. On The system is armed (can also be programmed for other indications)
Off The system is unarmed (can also be programmed for other indications)
Omit On One or more zones are omitted
Off No zones are omitted
Zone Faults During Arming
Before attempting to arm the system, ensure that the premises are secure (all doors and
windows closed etc.) and the Ready light is on.
If an attempt is made to arm the system with any zones active (e.g. door ajar, open
window, etc.) the internal sounders will bleep repeatedly (fault tone) and the display will
show the zones that are active.
The fault tone will stop and the exit tone will resume when all zones are secure. If it is
necessary to leave a zone open then it must be omitted (see page 8 for details).
!"
If an active zone cannot be secured then it may be ‘in fault’, in this case contact
the alarm company immediately.
Arm Fail - Failing to Arm
If the exit procedure is started and zones are still ‘Active’ at the end of the exit procedure,
an Internal alarm will occur (internal sounders only) and the strobe light on the external
sounder will flash.
!"
If this occurs the arm fail must be cleared and the zone in fault identified before the
system can be armed (see page 6 for details on clearing an Arm Fail).
The Ready LED
To help prevent faults during arming a Ready light has been provided, see table above
for details on how the Ready LED operates.

Other manuals for Texecom Premier 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier 24 and is the answer not in the manual?

Texecom Premier 24 Specifications

General IconGeneral
BrandTexecom
ModelPremier 24
CategoryControl Panel
LanguageEnglish

Related product manuals