4INS036-5
To UNSET the System
Enter via a designated entry route. The slow entry tone will start. Enter
your 4 digit code

. The system will unset and the entry tone
will stop.
During the last 10 seconds of the entry period the entry tone will
change from slow to fast.
To OMIT Zones During Setting
It is possible to exclude (omit) or include individual zones during setting.
Enter your 4 digit code

. Press
or enter Part Set
Suite number
or
and press
. Press
. The exit tone and
exit timer will stop and the display will illuminate the zones that are about
to be armed. Press the appropriate numbered button(s)
of the
zone(s) to be omitted or included. Press
to complete the
omitting procedure. The system will revert to exit mode. The exit tone and
exit timer will restart.
1. The system may be programmed so that some zones cannot be
omitted.
2. The system will automatically revert to exit mode 16 seconds after
the last key is pressed.
3. Whilst omitting, included zones that are in fault are indicated by
flashing.
4. Omitted zones that are not in fault flash during the exit period. If a
zone is illuminated but the system sounds the exit tone (as
opposed to an error tone) then the open zone is omitted.
To Set the System With a Power Fault
Enter your 4 digit code

. Press
or enter Part Set
Suite number
or
and press
. The system will sound a
repeating series of 10 bleeps. Press
. The display will illuminate the
zones that are about to be armed. Press
. The Power light will turn off.
Press
. The exit tone and exit timer will restart.
To RESET During an Alarm Activation
To silence the alarm enter your 4 digit code

. The internal and
external sounders will stop but the external strobe will continue to flash.
The display will flash the zone light of the zone which first caused the
alarm activation and illuminate the zone lights of all subsequently opened
zones (if any). To cancel the display and stop the external strobe press
. The system will chime and return to unset.

Other manuals for Texecom Veritas R8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Veritas R8 and is the answer not in the manual?

Texecom Veritas R8 Specifications

General IconGeneral
Zones8
Tamper ProtectionYes
Power Supply230V AC
KeypadLED keypad
Part Set Suites2
User Codes6 user codes
Event LogNo

Related product manuals