INS036-5 7
To Walk Test the System
The control panel has a Walk Test facility to check the operation of the
system's detection devices. Enter your 4 digit code

. The
Unset light will flash. Press
. All the zone lights will illuminate.
Enter

.
Initially all the zone lights will turn off and the control panel will sound the
quiet exit tone. When any zone is opened the control panel will illuminate
the corresponding zone light. The control panel will in addition sound a
repeating series of bleeps corresponding to the open zone number (i.e.
Zone 1 bleeps once, Zone 2 bleeps twice, etc.). If more than one zone is
open the bleeps will correspond to the highest zone number (e.g. if Zone
2 and Zone 6 are open the control panel will bleep 6 times).
Conduct a walk test by triggering each of the systems detection devices
in turn and check that the control panel registers the corresponding zone
as open. To terminate Walk Test press
. All the zone lights will
illuminate. Press
again. The system will return to unset and all the
zone lights will turn off.
To Change Your Code
Before changing your code, it is vital that you memorise or write
down the new code you are about to program. Failure to
remember your code will require an engineer visit to re-program
a new code for you. This may incur a call-out charge.
Enter your existing 4 digit code

. The Unset light will flash.
Press
. All the zone lights will illuminate. Enter

. All the zone
lights will turn off. Enter your new 4 digit code

. Zone lights 1,
2, 3 and 4 will illuminate in turn as each digit of the new code is entered.
Press
. The system will chime to confirm the new code has been
accepted and all the zone lights will illuminate. Press
. The
system will return to unset and all the zone lights will turn off.
If Your System is Due for Maintenance
The system has a service timer which may be programmed by the
installer to give a reminder when maintenance in due. The reminder may
be either turning Chime on or preventing the system from being set.
Chime may be turned off as previously described. In either case contact
your installer.
To Activate Keypad Personal Attack
The system has the ability to activate a Personal Attack Alarm from the
keypad. Press
&
together.

Other manuals for Texecom Veritas R8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Veritas R8 and is the answer not in the manual?

Texecom Veritas R8 Specifications

General IconGeneral
Zones8
Tamper ProtectionYes
Power Supply230V AC
KeypadLED keypad
Part Set Suites2
User Codes6 user codes
Event LogNo

Related product manuals