16
Trouble Shooting
Issues of hot water supply and temperature
Hot water
temperature is
unstable
Fully turn on the main water supply valve to ensure sufficient water
pressure.
Increase hot water flow of mixing-type faucet to avoid the hot water flow
lower than the minimum hot water flow that burner will be turned off.
Unable to adjust hot
water temperature
setting
Confirm the using front panel control or remote control has the priority and
check if the priority indicator lights up.
When appliance is in operation, hot water temperature can only be set to
48°C or below. If hot water temperature is set at 50°C or above, hot water
temperature can only be decreased.
Issues of front panel control, remote control and appliance operation
ON/OFF indicator
does not light up
Check if the power supply is normal.
After turning on the power supply of appliance, press the ON/OFF button
on front panel control or remote control.
Hot water
temperature setting
change automatically
When the appliance is in standby mode for more than 10 minutes, priority
will be released. If hot water temperature is set at 50°C or above, hot
water temperature will be returned to 48°C when the priority is released.
Fan keeps operating
without use of hot
water
After the burner is closed, combustion fan will keep operating for a short
period of time. This is a normal phenomenon.
Flame failure during
usage
Fully turn on the gas meter valve and/or gas supply valve of appliance.
Check if the gas supply is normal and without suspension.
Fully turn on the cold water valve and/or hot water tap.
Check if the water is running out from water tap normally.
Cloudy mist emerges
from flue terminal
In cold and humid weather, white mist is the condensate of water vapour
in flue gases. This is a normal phenomenon.
Hot water turns milky
with a cloudy status
Dissolved air in water is released as bubbles when heated. This is normal
phenomenon.
Water is discharged
momentarily from the
outlet of pressure
relief valve
If the water pressure inside the appliance is over the design pressure
value, the pressure relief valve located near the hot water outlet will be
opened to release pressure. After reducing to the design pressure value,
it will then be closed.