Bad Block scan Yes to start scan Bad Block.
Total Capacity Shows the total SATA hard disk capacity.
Disk Power
Management
The administrator can set the disk to power down after a period of
inactivity.
S.M.A.R.T. Information
On the Disks Information screen, the status of each disk will be displayed in the
Status column. Clicking on an OK or Warning link will display the S.M.A.R.T
Information window for that particular disk.
You may also perform disk SMART test, simply to click “Test” to start with. The
result is only for reference and system will not take any action from its result.
S.M.A.R.T. Information
Item Description
Tray Number Tray the hard disk is installed in.
Model Model name of the installed hard disk.
Power ON Hours
Count of hours in power-on state. The raw value of this attribute
shows total count of hours (or minutes, or seconds, depending on
manufacturer) in power-on state.
Temperature Celsius The current temperature of the hard disk in degrees Celsius
Reallocated Sector
Count
Count of reallocated sectors. When the hard drive finds a
read/write/verification error, it marks this sector as "reallocated"
and transfers data to a special reserved area (spare area).
This process is also known as remapping and "reallocated" sectors
are called remaps. This is why, on a modern hard disks, you can
not see "bad blocks" while testing the surface - all bad blocks are
hidden in reallocated sectors. However, the more sectors that are
reallocated, the more a decrease (up to 10% or more) can be
noticed in disk read/write speeds.
NOTE
When the Status shows
hard disk. It is shown
drives.
Warning, it usually means there are bad sectors on the
only as a precaution and you should consider changing the
49

Table of Contents

Other manuals for Thecus N7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N7700 and is the answer not in the manual?

Thecus N7700 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, JBOD
Storage drive size3.5 \
Storage drive capacity- GB
Storage drive interfaceSerial ATA
Total installed storage capacity14 TB
Number of storage drives installed0
Number of storage drives supported7
Flash memory128 MB
Internal memory2 GB
Internal memory typeDDR2
Processor frequency1.86 GHz
iSCSI supportYes
Supported network protocolsSMB/CIFS, HTTP/HTTPS, FTP, NFS v3, AFP
Compliance industry standards802.3ad
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
Dimensions (WxDxH)210 x 270 x 320 mm
Management platformLinux
Compatible operating systemsWindows 7/2000/XP/2003/Vista UNIX/Linux Mac OS 9 / X
Power supply unit (PSU) capacity300 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight8600 g