EasyManuals Logo

Thecus N7700 User Manual

Thecus N7700
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
NOTE
Migrating a RAID volume could take several hours to complete
With RAID level migration function, it has two different type “On line” and “Off line”
alone with limitation as listed below.
1. During RAID level migration, it is not allowed reboot or shutdown system.
2. Off line RAID level migration, all services will stop and data is inaccessible.
3. To have ZFS file system created doing on line RAID level migration from R1
to R5 or R1 to R6, the all services will restart and volumes “user data”
and “iSCSI” are read only during operation.
4. To have ext3 and XFS file system created doing on line RAID level
migration from R1 to R5 or R1 to R6, the all services will restart and
volumes “iSCSI” is read only but “user data” is capable read / write during
operation.
5. The other combination to make as “On line” can have read / write work as
normal.
58

Table of Contents

Other manuals for Thecus N7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N7700 and is the answer not in the manual?

Thecus N7700 Specifications

General IconGeneral
RAID levels0, 1, 5, 6, 10, JBOD
Storage drive size3.5 \
Storage drive capacity- GB
Storage drive interfaceSerial ATA
Total installed storage capacity14 TB
Number of storage drives installed0
Number of storage drives supported7
Flash memory128 MB
Internal memory2 GB
Internal memory typeDDR2
Processor frequency1.86 GHz
iSCSI supportYes
Supported network protocolsSMB/CIFS, HTTP/HTTPS, FTP, NFS v3, AFP
Compliance industry standards802.3ad
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
Dimensions (WxDxH)210 x 270 x 320 mm
Management platformLinux
Compatible operating systemsWindows 7/2000/XP/2003/Vista UNIX/Linux Mac OS 9 / X
Power supply unit (PSU) capacity300 W
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight8600 g