Below is a table listing of possible RAID migration schemes:
To
From RAID 0 RAID 5 RAID 6
RAID
0
[OFFLINE]
[RAID 0] HDDx2 to [RAID 0] HDDx3
[RAID 0] HDDx2 to [RAID 0] HDDx4
[RAID 0] HDDx2 to [RAID 0] HDDx5
[RAID 0] HDDx2 to [RAID 0] HDDx6
[RAID 0] HDDx2 to [RAID 0] HDDx7
[RAID 0] HDDx3 to [RAID 0] HDDx4
[RAID 0] HDDx3 to [RAID 0] HDDx5
[RAID 0] HDDx3 to [RAID 0] HDDx6
[RAID 0] HDDx3 to [RAID 0] HDDx7
[RAID 0] HDDx4 to [RAID 0] HDDx5
[RAID 0] HDDx4 to [RAID 0] HDDx6
[RAID 0] HDDx4 to [RAID 0] HDDx7
[RAID 0] HDDx5 to [RAID 0] HDDx6
[RAID 0] HDDx5 to [RAID 0] HDDx7
[RAID 0] HDDx6 to [RAID 0] HDDx7
[OFFLINE]
[RAID 0] HDDx2 to [RAID 5] HDDx3
[RAID 0] HDDx2 to [RAID 5] HDDx4
[RAID 0] HDDx2 to [RAID 5] HDDx5
[RAID 0] HDDx2 to [RAID 5] HDDx6
[RAID 0] HDDx2 to [RAID 5] HDDx7
[RAID 0] HDDx3 to [RAID 5] HDDx4
[RAID 0
] HDDx3 to [RAID 5] HDDx5
[RAID 0] HDDx3 to [RAID 5] HDDx6
[RAID 0] HDDx3 to [RAID 5] HDDx7
[RAID 0] HDDx4 to [RAID 5] HDDx5
[RAID 0] HDDx4 to [RAID 5] HDDx6
[RAID 0] HDDx4 to [RAID 5] HDDx7
[RAID 0] HDDx5 to [RAID 5] HDDx6
[RAID 0] HDDx5 to [RAID 5] HDDx7
[RAID 0] HDDx6 to [RAID 5] HDDx7
X
RAID
1
[OFFLINE]
[RAID 1] HDDx2 to [RAID 0] HDDx2
[RAID 1] HDDx2 to [RAID 0] HDDx3
[RAID 1] HDDx2 to [RAID 0] HDDx4
[RAID 1] HDDx2 to [RAID 0] HDDx5
[RAID 1] HDDx2 to [RAID 0] HDDx6
[RAID 1] HDDx2 to [RAID 0] HDDx7
[RAID 1] HDDx3 to [RAID 0] HDDx4
[RAID 1] HDDx3 to [RAID 0] HDDx5
[RAID 1] HDDx3 to [RAID 0] HDDx6
[RAID 1] HDDx3 to [RAID 0] HDDx7
[RAID 1] HDDx4 to [RAID 0] HDDx5
[RAID 1] HDDx4 to [RAID 0] HDDx5
[RAID 1] HDDx4 to [RAID 0] HDDx6
[RAID 1] HDDx5 to [RAID 0] HDDx6
[RAID 1] HDDx5 to [RAID 0] HDDx7
[RAID 1] HDDx6 to [RAID 0] HDDx7
[RAID 1] HDDx7 to [RAID 0] HDDx7
[ONLINE]
[RAID 1] HDDx2 to [RAID 5] HDDx3
[RAID 1] HDDx2 to [RAID 5] HDDx4
[RAID 1] HDDx2 to [RAID 5] HDDx5
[RAID 1] HDDx2 to [RAID 5] HDDx6
[RAID 1] HDDx2 to [RAID 5] HDDx6
[RAID 1] HDDx3 to [RAID 5] HDDx4
[RAID 1
] HDDx3 to [RAID 5] HDDx5
[RAID 1] HDDx3 to [RAID 5] HDDx6
[RAID 1] HDDx3 to [RAID 5] HDDx7
[RAID 1] HDDx4 to [RAID 5] HDDx5
[RAID 1] HDDx4 to [RAID 5] HDDx6
[RAID 1] HDDx4 to [RAID 5] HDDx7
[RAID 1] HDDx5 to [RAID 5] HDDx6
[RAID 1] HDDx5 to [RAID 5] HDDx7
[RAID 1] HDDx6 to [RAID 5] HDDx7
[ONLINE]
[RAID 1] HDDx2 to [RAID 6] HDDx4
[RAID 1] HDDx2 to [RAID 6] HDDx5
[RAID 1] HDDx2 to [RAID 6] HDDx6
[RAID 1] HDDx2 to [RAID 6] HDDx6
[RAID 1] HDDx3 to [RAID 6] HDDx4
[RAID 1] HDDx3 to [RAID 6] HDDx5
[RAID 1]
HDDx3 to [RAID 6] HDDx6
[RAID 1] HDDx3 to [RAID 6] HDDx7
[RAID 1] HDDx4 to [RAID 6] HDDx5
[RAID 1] HDDx4 to [RAID 6] HDDx6
[RAID 1] HDDx4 to [RAID 6] HDDx7
[RAID 1] HDDx5 to [RAID 6] HDDx6
[RAID 1] HDDx5 to [RAID 6] HDDx7
[RAID 1] HDDx6 to [RAID 6] HDDx6
[RAID 1] HDDx6 to [RAID 6] HDDx7
RAID
5
X [ONLINE]
[RAID 5] HDDx3 to [RAID 5] HDDx4
[RAID 5] HDDx3 to [RAID 5] HDDx5
[RAID 5] HDDx3 to [RAID 5] HDDx6
[RAID 5] HDDx3 to [RAID 5] HDDx7
[RAID 5] HDDx4 to [RAID 5] HDDx5
[RAID 5] HDDx4 to [RAID 5] HDDx6
[RAID 5] HDDx4 to [RAID 5] HDDx7
[RAID 5] HDDx5 to [RAID 5] HDDx6
[RAID 5] HDDx5 to [RAID 5] HDDx7
[RAID 5] HDDx6 to [RAID 5] HDDx7