Fault This may mean Cause Solution
Output is
restricted and
can not be
controlled�
Connection
failure�
Input or output
connection leads�
Check all input and output
connection cables�
Fluctuating
connection
between the clamp
and workpiece�
Ensure that the work lead has
a good connection to a clean
and dry area of workpiece�
Cut quality
issues�
Incorrect current
setting�
Low current or high
material thickness�
Adjust the current to suit
the thickness of material
to be cut�
Consumables
fault�
Consumables are
worn�
Inspect consumables – see
section Consumable part
inspection�
Incorrect cutting
technique�
Poor cut quality Adjust the current to suite
the cutting speed and
torch-to-workpiece distance
according to the thickness
of material to be cut�
Poor connection� Workpiece is dirty /
contaminated�
Clean the surface