37
Table 12 - Air Cooled Chiller Electrical Data (60 Hz) - continued
Model
Process
Pump
Size
Rated
Voltage
Allowable
Power
Compressor Data
Condenser Fan Data
Pump
Data
Unit Data
Comp 1
Comp 2
Fan 1
Fan 2
Fan 2
Min
Max
RLA
1
LRA
2
RLA
1
LRA
2
FLA
3
FLA
3
FLA
3
FLA
3
MCA
4
MOP
5
NQA25
None
230/3/60
207
253
51.3
300.0
51.3
300.0
8.3
8.3
-
0.0
134.5
185.8
5 HP
230/3/60
207
253
51.3
300.0
51.3
300.0
8.3
8.3
-
15.2
149.7
201.0
7.5 HP
230/3/60
207
253
51.3
300.0
51.3
300.0
8.3
8.3
-
22.0
156.5
207.8
10 HP
230/3/60
207
253
51.3
300.0
51.3
300.0
8.3
8.3
-
28.0
162.5
213.8
None
460/3/60
414
506
23.1
150.0
23.1
150.0
4.6
4.6
-
0.0
62.4
85.5
5 HP
460/3/60
414
506
23.1
150.0
23.1
150.0
4.6
4.6
-
7.6
70.0
93.1
7.5 HP
460/3/60
414
506
23.1
150.0
23.1
150.0
4.6
4.6
-
11.0
73.4
96.5
10 HP
460/3/60
414
506
23.1
150.0
23.1
150.0
4.6
4.6
-
14.0
76.4
99.5
None
575/3/60
518
633
19.9
109.0
19.9
109.0
3.7
3.7
-
0.0
53.1
73.0
5 HP
575/3/60
518
633
19.9
109.0
19.9
109.0
3.7
3.7
-
6.1
59.2
79.1
7.5 HP
575/3/60
518
633
19.9
109.0
19.9
109.0
3.7
3.7
-
8.8
61.9
81.8
10 HP
575/3/60
518
633
19.9
109.0
19.9
109.0
3.7
3.7
-
11.2
64.3
84.2
NQA30
None
230/3/60
207
253
55.8
340.0
55.8
340.0
8.3
8.3
8.3
0.0
153.0
208.8
5 HP
230/3/60
207
253
55.8
340.0
55.8
340.0
8.3
8.3
8.3
15.2
168.2
224.0
7.5 HP
230/3/60
207
253
55.8
340.0
55.8
340.0
8.3
8.3
8.3
22.0
175.0
230.8
10 HP
230/3/60
207
253
55.8
340.0
55.8
340.0
8.3
8.3
8.3
28.0
181.0
236.8
None
460/3/60
414
506
26.9
173.0
26.9
173.0
4.6
4.6
4.6
0.0
75.5
102.4
5 HP
460/3/60
414
506
26.9
173.0
26.9
173.0
4.6
4.6
4.6
7.6
83.1
110.0
7.5 HP
460/3/60
414
506
26.9
173.0
26.9
173.0
4.6
4.6
4.6
11.0
86.5
113.4
10 HP
460/3/60
414
506
26.9
173.0
26.9
173.0
4.6
4.6
4.6
14.0
89.5
116.4
None
575/3/60
518
633
23.7
132.0
23.7
132.0
3.7
3.7
3.7
0.0
65.3
89.0
5 HP
575/3/60
518
633
23.7
132.0
23.7
132.0
3.7
3.7
3.7
6.1
71.4
95.1
7.5 HP
575/3/60
518
633
23.7
132.0
23.7
132.0
3.7
3.7
3.7
8.8
74.1
97.8
10 HP
575/3/60
518
633
23.7
132.0
23.7
132.0
3.7
3.7
3.7
11.2
76.5
100.2
1
RLA is Rated Load Amps.
2
LRA is Locked Rotor Amps.
3
FLA is Full Load Amps.
4
MCA is Minimum Circuit Amps (for wire sizing), complies with NEC, Section 430-24.
5
MOPD is Maximum Over-current Protection Device, complies with NEC, Section 430-53.