Caution Depending on the condition of power supply, unstable power or volt-
age may cause malfunction of the parts or control system.
Do not install the heat pump in following places:
The place where there is mineral oil or arsenic acid. There is a chance that parts may get damaged due to burned resin. The capacity
of the heat exchanger may reduce or the Air to Water Heat pump may be out of order.
The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet. The copper pipe or connection
pipe may corrode and refrigerant may leak.
The place where there is a danger of existing combustible gas, carbon fiber or flammable dust. The place where thinner or gasoline
is handled.
N
Adhere to national regulations regarding noise interference.
If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position. Make sure that the water dripping from the drain
hose runs away correctly and safely.